System Config > Faults
Configure Fault Reporting options. See
Fault Reporting
Set SMTP server, Domain name overrides, Return address, and other options. See
next.
SMTP server—Use a hostname or IP address to set the mail relay to use to send
notification emails. Use no email mailhub to clear the entry.
Domain name override—Use a hostname or IP address to set the domain name from
which emails are to appear to come (provided that the return address is not already fully-
qualified). This is used in conjunction with the system hostname to form the full name of
the host from which the email appears to come. The rules are as follows:
a. If an email domain is specified using this command, it is always used. If the hostname
has any dots in it, everything to the right of the first dot is stripped and the email
domain is appended.
b. Otherwise, if the hostname has dots in it, it is used as is.
Otherwise, the currently-active system domain name is used. This can come either from
the resolver configuration, or from state dynamically instantiated by DHCP.
Return address—Set the username or fully-qualified return address from which email
notifications are sent. If the string provided contains an at (@) sign, it is considered fully-
qualified and is used as-is. Otherwise, it is considered just the username, and MFD
appends @<hostname>.<domain>. The default is do-not-reply, but this can be changed
to admin or as desired in case something along the line doesn't like fictitious addresses.
Include hostname in return addr—Include (or do not include by un-checking) the
hostname in the return address for email notifications. This only takes effect if the return
address does not contain an at (@) sign.
Enable autosupport notifications—Enable or disable (by un-checking) the sending of
email to vendor autosupport when certain failures occur.
Click Apply to complete Fault notification configuration, Cancel to revert to existing
configuration. Click Save at the top of the page to make changes persistent across reboots.