EPSON Stylus PHOTO 2100/2200
"
When removing the Paper Eject Roller Shaft A, the following
adjustments are necessary. Make the adjustments in the
following order.
1.
PG adjustment
2.
CR tooth skip prevention mechanism adjustment
3.
Head cleanig
4.
Head angular adjustment
5.
Bi-D adjustment
6.
Pixel Shift Adjustment
7.
PF adjustment
"
Refer to "Chapter 5 Adjustment" for the adjustment
procedures.
"
After changing the Grounding Spring for a new one, always
apply grease G-26 in the specified position.
Refer to Chapter 6, Figure 6-7, "Lubrication Point 9".
DISASSEMBLY AND ASSEMBLY
4.2.17 Removing the PF Roller Support
1.
Remove the PF Roller. (Refer to 4.2.15.)
2.
Remove the Under Driven Roller.
Figure 4-136. Removing the Under Driven Roller
3.
Remove the two screws 6) C.B.S 3
Support, and slide the PF Roller Support to the top to remove it from the Upper
Frame.
Hook
C.B.S 3x6
Hook
Figure 4-137. Removing the PF Roller Support
Disassembly
Revision B
Under Driven
Roller
×
6 (9±1kgf.cm) that secure the PF Roller
Joggle
Hook
C.B.S 3x6
PF Roller Support
Hook
181