EPSON Stylus PHOTO 2100/2200
Hook
Projection
2
Figure 4-103. Removing the PE Sensor Unit
When reinstalling the PE Sensor Unit, secure it with three hooks.
Refer to Figure 4-103, "Removing the PE Sensor Unit".
DISASSEMBLY AND ASSEMBLY
Hooks
1
1
Hook
PE Sensor
Unit
3
6.
Disconnect the Connector Cables, which are connected to the PE Sensor, from the
PE Sensor Connector and hook, and remove the PE Sensor Unit.
7.
Release the PE Sensor Fixing Hook that secures the PE Sensor to the PE Sensor
Unit, and remove the PE Sensor.
PE Sensor
PE Sensor Fixing Hook
Figure 4-104. Removing the PE Sensor
When connecting the Connector to the PE Sensor, hitch the
Connector Cables on the hook.
Refer to Figure 4-104, "Removing the PE Sensor".
Disassembly
Revision B
Connector
Connector
Cable
Hook
167