Removing and Replacing the Chassis Cover

This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that
Warning
the protective device is rated not greater than 120 VAC, 20 A U.S. (240 VAC, 16-20 A International).
Statement 1005
Warning
This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the
absence of a suitably installed ground conductor. Contact the appropriate electrical inspection
authority or an electrician if you are uncertain that suitable grounding is available. Statement 1024
Warning
Blank faceplates and cover panels serve three important functions: they prevent exposure to
hazardous voltages and currents inside the chassis; they contain electromagnetic interference (EMI)
that might disrupt other equipment; and they direct the flow of cooling air through the chassis. Do not
operate the system unless all cards, faceplates, front covers, and rear covers are in place. Statement
1029
Warning
This unit might have more than one power supply connection. All connections must be removed to
de-energize the unit. Statement 1028
Caution
Follow proper safety procedures when removing and replacing the chassis cover by reading the safety
warnings in
4200 Series Appliance
This section describes how to remove and replace the IDS-4215 chassis cover. It contains the following
topics:

Removing the Chassis Cover

Removing the appliance chassis cover does not affect your Cisco warranty. Upgrading IDS-4215 does
Note
not require any special tools and does not create any radio frequency leaks.
To remove the chassis cover, follow these steps:
Step 1
Log in to the CLI.
Step 2
Prepare IDS-4215 to be powered off:
sensor# reset powerdown
Wait for the power down message before continuing with Step 3.
78-16124-01
Regulatory Compliance and Safety Information for the Cisco Intrusion Prevention System
Sensor.
Removing the Chassis Cover, page 3-11
Replacing the Chassis Cover, page 3-13
Installing Cisco Intrusion Prevention System Appliances and Modules 5.0

Removing and Replacing the Chassis Cover

3-11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents