Configuring Cisco 10000 Series Router PXF Stall Monitor

Configuring Cisco 10000 Series Router PXF Stall Monitor
This section describes how to configure and monitor the Cisco 10000 Series Router PXF Stall Monitor
feature.
SUMMARY STEPS
1.
2.
3.
4.
5.
6.
DETAILED STEPS
Command or Action
Step 1
enable
Example:
Router> enable
Step 2
configure terminal
Example:
Router# configure terminal
Step 3
hw-module pxf stall-monitoring
Example:
Router(config)# hw-module pxf stall-monitoring
Step 4
hw-module pxf stall-monitoring [HT-Reset <4-6>
| LC-Reset <4-6>]
Example:
Router(config)# hw-module pxf stall-monitoring
HT-Reset 4
Cisco 10000 Series Router Software Configuration Guide
17-64
PSM cannot detect a LC that gets stalled before interfaces come up on the LC.
PSM cannot detect stalls in LCs where multiple link bundling is done across LCs.
PSM state in the active PRE is not synchronized with the standby PRE, even in SSO mode.
Therefore, during a switchover from active PRE to standby PRE, there is a delay in detecting a stall
that occurred during the switchover.
Management ports available on the PRE is not monitored by PSM.
enable
configure terminal
hw-module pxf stall-monitoring
hw-module pxf stall-monitoring [HT-Reset 4-6 | LC-Reset 4-6]
exit
show pxf stall-monitoring [counters | reset {active-status | cob-fib | cob-tib | pxf-drop} subslot
sub slot]
Chapter 17
Cisco 10000 Series Router PXF Stall Monitor
Purpose
Enables privileged EXEC mode.
Enter your password if prompted.
Enters the global configuration mode.
Enables PSM on the Cisco 10000 series router. By default,
the threshold values of LC and HTDP reset are set to 3. The
default threshold values for LC and HTDP can be changed
using the hw-module pxf stall-monitoring command
again.
Configures the threshold value for LC and HTDP reset
before the secondary action, PRE switchover, takes place
using the following parameters:
HT-Reset 4-6—Specifies the threshold value for HTDP
reset. You can configure the value ranging from 4 to 6.
LC-Reset 4-6—Specifies the threshold value for LC
reset. You can configure the value ranging from 4 to 6.