6.1 RF Output
The minimum RF output power is 10 W with the RF load VSWR < 2:1 at all phase angles from 0 to 360 degrees.
6.2 Electrical Current
The electrical current drain for TIMTER™ transmitters is provided in Table 13.
Band Type
L or S band
L/S band (4x3)
C band
L/C band or S/C band (4x3)
L/S/C band (4x3)
6.3 Environmental Specifications
TIMTER™ transmitters meet the environmental requirements shown in Table 14.
Environmental Specifications
Operating temperature (5 W per Output)
Operating temperature (10 W per Output)
Non-operating temperature (all models)
Operating humidity
Altitude
6.3.1
EMI Performance
Every Quasonix transmitter is designed to operate reliably and unobtrusively in the most challenging environments.
This includes electromagnetic interference and compatibility (EMI/EMC) requirements. More specifically, all
Quasonix transmitters in the TIMTER™ family (2 cubic inches and above) have been designed to comply with the
following requirements of MIL-STD-461G (and MIL-STD-461E and -461F, when those now-obsolete standards
have been applied):
86
Quasonix, Inc.
6 Performance Specifications
Table 13: DC Input Current at Standard Input Voltage
Wattage
10 Watts per Output
10 Watts per Output
10 Watts per Output
10 Watts per Output
10 Watts per Output
Table 14: TIMTER™ Environmental Specifications
TIMTER™ Multi-mode Dual
Telemetry Transmitter
Maximum
Typical Current
Current
@ 28 VDC
3.5 amps
3.2 amps
3.5 amps
3.2 amps
3.8 amps
3.5 amps
5.0 amps
4.5 amps
5.0 amps
4.5 amps
Description
-40°C to +85°C
-40°C to +70°C
-55°C to +100°C
0 to 95% (non-condensing)
Up to 100,000 ft.