Mnemonic
Name
Command
PAT
PA Attenuator
PF
PSK Filter Select
PL
Power Level
55
Quasonix, Inc.
Description
This is a read only command to
display the current attenuator
settings
Examples:
PAT
Reports PA attenuator
setting in dB
PAT D Displays the current table
PAT L Displays L band
attenuator values
PAT 1435.5 Displays the
attenuator value for frequency
1435.5
Sets or shows the current PSK
filter selection; This is valid if the
PSK mode option is enabled and
for any *PSK (legacy) modes
AND for DPM (no option
required) if that mode exists on
the transmitter.
Valid filter range is 0 to 255
Examples:
PF
Show current PSK filter
PF 42 Set PSK filter to 42
This is a read only command;
PL reports the current power level
setting for the dual power feature
Examples:
PL
Report the current power
level state
Disabled in Parallel Mode
TIMTER™ Multi-mode Dual
Telemetry Transmitter
Option (s)
Setting
Required
Saved?
Standard
N/A
All *PSK
Y
DP
Y
Factory
Default
N/A
PF 255
(PF 10 if
DPM)
PL 0