6.10.2 Shock Testing
In addition to vibration testing, the UUT was subjected to shock pulses, as follows:
•
Type:
•
Level:
•
Duration:
Application: Three (3) shocks in each direction of the three (3) orthogonal axes both positive and negative, for 18
shocks total
The plots of the positive and negative pulses in each of the three axes are shown in the following figures:
98
Quasonix, Inc.
Half-sine
60 g
5 milliseconds
Figure 41: Shock Pulse, Z-axis Positive