The valid step size range is >= 1 kHz to <= 1000 MHz.
The frequency sweep syntax is:
SW [chan [enable [start stop step]]]
Where:
channel is 1, 2, or 3 for both channels
enable is 0 for Off, 1 to enable (On)
start is starting frequency in MHz
stop is ending frequency in MHz
step is frequency step size in MHz
SW ? displays help (syntax)
SW displays current status
SW chan shows state of specified channel sweep
Examples:
SW ?
Help (syntax)
SW
Show the sweep status for the current channel
SW 2
Show the sweep status for channel 2
SW 1 1 1435.5 1442.0 1
stop frequency is 1442.0 MHz, sweep frequency step size is 1 MHz
4.2.3.1.19 System Status – SY
The status reporting period must be > 200 ms or zero (0) to disable. Items in the SY command are defined with the
SZ command. The minimum update period is 200 ms (about 5 times per second).
The SY command is defined as follows.
Mode - Current mode number (such as 0 = PCM/FM)
CF Rate - Clock free estimated data rate. This rate is based on the external data input (TTL or RS-422) even if
internal data is presently in use (CS = 1).
Freq - Tuned frequency
Tmp - Current temperature
CRate - Clock filter clock rate. This is the actual over the air bit rate, regardless of the selected data source, and
including any increases due to encoding (LDPC or convolutional). IN clock free automatic mode, it may differ from
CF Rate because it will track the bit sync rate (exact, if locked) rather than the clock free estimated rate
(approximate).
78
Quasonix, Inc.
Set channel 1 to enable (On), the start frequency is 1435.5 MHz, the
TIMTER™ Multi-mode Dual
Telemetry Transmitter
Need help?
Do you have a question about the TIMTER and is the answer not in the manual?