CS
CF
D2
BR auto/manual
1
x
x
0
0
0
Auto
0
0
0
Auto
0
0
0
Auto
0
0
0
Manual
0
0
1
Auto
0
0
1
Auto
0
0
1
Auto
0
0
1
Manual
0
1
x
0
1
x
0
1
x
*Note that 'x' means 'don't care'; Blue cells denote channel specific settings, the rest are global to the dual transmitter
112
Quasonix, Inc.
Ext Clk In
Ext Dat In
x
x
x
present
x
not present
x
not present
x
present
(should be
Channel 2
data stream)
not present
not present
x
x
present
x
not present
x
not present
Channel 2
AC
x
x
RF out is based on Channel 2 IC and ID
x
RF out is based on auto CF rate derived from ext dat input
0
RF off
1
RF stick at carrier frequency
x
x
RF out based on Channel 2 BR setting (may be trash if no
data is present or rate is wrong on ext dat input)
x
x
RF out is based on Channel 2 auto CF rate derived from
data at the ext clk input
x
0
RF off
x
1
RF stick at carrier frequency
x
x
RF out based on Channel 2 BR setting (may be trash if no
data is present or rate is wrong on ext clk input)
x
x
RF out based on ext clock and data (may be trash if no
data is present on ext dat input)
x
0
RF off
x
1
RF stick at carrier frequency