Download Print this page

Tektronix KEITHLEY System SourceMeter 2636B Reference Manual page 912

Advertisement

Appendix F: Model 2400 emulation
Subsystem Command
:SOURce
:SOURce2:BSIZe 3|4
:SOURce
:SOURce2:BSIZe?
:SOURce2:CLEar:AUTO <Bool>
:SOURce
:SOURce
:SOURce2:CLEar:AUTO?
:SOURce
:SOURce2:CLEar:AUTO:DELay <NRf>|DEFault|MINimum|MAXimum
:SOURce
:SOURce2:CLEar:AUTO:DELay? [DEFault|MINimum|MAXimum]
:SOURce
:SOURce2:CLEar[:IMMEdiate]
:SOURce
:SOURce2:TTL[:LEVel]:ACTual?
:SOURce
:SOURce2:TTL[:LEVel][:DEFault] <NDN>|<NRf>
:SOURce2:TTL[:LEVel][:DEFault]?
:SOURce
:SOURce
:SOURce2:TTL4:BSTate <Bool>
:SOURce
:SOURce2:TTL4:BSTate?
:SOURce
:SOURce2:TTL4:MODE EOTest|BUSY
:SOURce2:TTL4:MODE?
:SOURce
:STATus
:STATus:MEASurement:CONDition?
:STATus
:STATus:MEASurement:ENABle <NDN>|<NRf>
:STATus
:STATus:MEASurement:ENABle?
:STATus:MEASurement[:EVENt]?
:STATus
:STATus
:STATus:OPERation:CONDition?
:STATus
:STATus:OPERation:ENABle <NDN>|<NRf>
:STATus:OPERation:ENABle?
:STATus
:STATus
:STATus:OPERation[:EVENt]?
:STATus
:STATus:PRESet
:STATus
:STATus:QUEStionable:CONDition?
:STATus
:STATus:QUEStionable:ENABle <NDN>|<NRf>
:STATus
:STATus:QUEStionable:ENABle?
:STATus
:STATus:QUEStionable[:EVENt]?
:STATus
:STATus:QUEue:CLEar
:STATus:QUEue:DISable <list>
:STATus
:STATus
:STATus:QUEue:DISable?
:STATus
:STATus:QUEue:ENABle <list>
:STATus
:STATus:QUEue:ENABle?
:STATus
:STATus:QUEue[:NEXT]?
:SYSTem
:SYSTem:AZERo:CACHing:NPLCycles?
:SYSTem
:SYSTem:AZERo:CACHing:REFResh
:SYSTem
:SYSTem:AZERo:CACHing:RESet
:SYSTem:AZERo:CACHing[:STATe] <Bool>
:SYSTem
:SYSTem
:SYSTem:AZERo:CACHing[:STATe]?
:SYSTem
:SYSTem:AZERo[:STATe] <Bool>
:SYSTem:AZERo[:STATe]?
:SYSTem
:SYSTem
:SYSTem:BEEPer[:IMMediate] <NRf>,<NRf>
:SYSTem
:SYSTem:BEEPer:STATe <Bool>
:SYSTem
:SYSTem:BEEPer:STATe?
:SYSTem:CCHeck ON|OFF
:SYSTem
:SYSTem
:SYSTem:CCHeck?
:SYSTem
:SYSTem:CCHeck:RESistance <NRf>
:SYSTem
:SYSTem:CCHeck:RESistance?
:SYSTem:CLEar
:SYSTem
F-12
Series 2600B System SourceMeter® Instrument Reference Manual
2600BS-901-01 Rev. E / January 2019
Supported
Partially
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Partially
Partially
Partially
Partially
Partially
Partially
Yes
Yes
Yes
Yes
No
No
No
No
Yes

Advertisement

loading
Need help?

Need help?

Do you have a question about the KEITHLEY System SourceMeter 2636B and is the answer not in the manual?