Appendix F: Model 2400 emulation
Subsystem Command
:FORMat
:FORMat:ELEMents:CALCulate CALC|TIME|STATus
:FORMat
:FORMat:ELEMents:CALCulate?
:FORMat:ELEMents[:SENSe[1]] VOLTage|CURRent|RESistance|TIME|STATus
:FORMat
:FORMat
:FORMat:ELEMents[:SENSe[1]]?
:FORMat
:FORMat:SOURce2 ASCii|HEXadecimal|OCTal|BINary
:FORMat
:FORMat:SOURce2?
:FORMat
:FORMat:SREGister ASCii|HEXadecimal|OCTal|BINary
:FORMat
:FORMat:SREGister?
:MEASure
:CONFigure?
:CONFigure:CURRent[:DC]
:MEASure
:MEASure
:CONFigure:RESistance
:MEASure
:CONFigure:VOLTage[:DC]
:MEASure
:FETCh?
:MEASure?
:MEASure
:MEASure
:MEASure:CURRent[:DC]?
:MEASure
:MEASure:RESistance?
:MEASure
:MEASure:VOLTage[:DC]?
:OUTPut[1]:ENABle:STATe <Bool>
:OUTPut
:OUTPut
:OUTPut[1]:ENABle:STATe?
:OUTPut
:OUTPut[1]:ENABle:TRIPped?
:OUTPut[1]:SMODe HIMPedance|NORMal|ZERO|GUARd
:OUTPut
:OUTPut
:OUTPut[1]:SMODe?
:OUTPut
:OUTPut[1][:STATe] <Bool>
:OUTPut
:OUTPut[1][:STATe]?
:ROUte
:ROUTe:TERMinals FRONt|REAR
:ROUte
:ROUTe:TERMinals?
:SENSe[1]
[:SENSe[1]]:AVERage:COUNt <NRf>|DEFault|MINimum|MAXimum
:SENSe[1]
[:SENSe[1]]:AVERage:COUNt? [DEFault|MINimum|MAXimum]
[:SENSe[1]]:AVERage[:STATe] <Bool>
:SENSe[1]
:SENSe[1]
[:SENSe[1]]:AVERage[:STATe]?
:SENSe[1]
[:SENSe[1]]:AVERage:TCONtrol REPeat|MOVing
:SENSe[1]
[:SENSe[1]]:AVERage:TCONtrol?
:SENSe[1]
[:SENSe[1]]:CURRent[:DC]:NPLCycles <NRf>|DEFault|MINimum|MAXimum
:SENSe[1]
[:SENSe[1]]:CURRent[:DC]:NPLCycles? [DEFault|MINimum|MAXimum]
:SENSe[1]
[:SENSe[1]]:CURRent[:DC]:PROTection[:LEVel]
:SENSe[1]
[:SENSe[1]]:CURRent[:DC]:PROTection[:LEVel]?
:SENSe[1]
[:SENSe[1]]:CURRent[:DC]:PROTection:RSYNchronize <Bool>
[:SENSe[1]]:CURRent[:DC]:PROTection:RSYNchronize?
:SENSe[1]
[:SENSe[1]]:CURRent[:DC]:PROTection:TRIPped?
:SENSe[1]
:SENSe[1]
[:SENSe[1]]:CURRent[:DC]:RANGe:AUTO <Bool>
:SENSe[1]
[:SENSe[1]]:CURRent[:DC]:RANGe:AUTO?
[:SENSe[1]]:CURRent[:DC]:RANGe:AUTO:LLIMit <NRf>
:SENSe[1]
:SENSe[1]
[:SENSe[1]]:CURRent[:DC]:RANGe:AUTO:LLIMit?
:SENSe[1]
[:SENSe[1]]:CURRent[:DC]:RANGe:AUTO:ULIMit?
:SENSe[1]
[:SENSe[1]]:CURRent[:DC]:RANGe[:UPPer]
:SENSe[1]
[:SENSe[1]]:CURRent[:DC]:RANGe[:UPPer]?
:SENSe[1]
[:SENSe[1]]:DATA[:LATest]?
F-8
<NRf>|DEFault|MINimum|MAXimum
DEFault|MINimum|MAXimum
<NRf>|DEFault|MINimum|MAXimum|UP|DOWN
[DEFault|MINimum|MAXimum]
Series 2600B System SourceMeter® Instrument Reference Manual
2600BS-901-01 Rev. E / January 2019
Supported
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Partially
Partially
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Partially
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Need help?
Do you have a question about the KEITHLEY System SourceMeter 2636B and is the answer not in the manual?