Technical Information
YELLOW
GREEN
LED behavior in REMOTE mode.
OFF
RED
YELLOW
GREEN
A.3.1.3 ASDP
LED behavior in MASTER and SLAVE modes.
OFF
RED
YELLOW
GREEN
42
Balanced mode: the interface is awaiting data from the Central (serial) and/or Re-
mote sites (IP).
The serial interface is detected, the Control signal is active and the interface is
awaiting data from the Central (serial) and/or Remote sites (IP). (Transparent
mode)
Steady:
Unbalanced mode: Data has been received from the Central site and transmitted
to the Remote site (IP). Awaiting a response from the Remote site.
(Non-transparent mode)
Balanced mode: Data has been received from the Central site and sent to the Re-
mote site (IP). Awaiting a response from the Remote site. Alternatively, data has
been received from the Remote site and sent to the Central site (serial). Awaiting
a response from the Central site. (Non-transparent mode)
Flashing: Data is being transferred through the serial interface. (For all modes).
The serial interface has not been detected/installed, is configured as DOWN, or
the Control signal is inactive.
The serial interface is detected, the Control signal is active, and:
Unbalanced mode: the interface is awaiting data from the Central site (IP).
Balanced mode: the interface is awaiting data from the Central (IP) and/or Remote
sites (serial).
The serial interface has been detected, the Control signal is active and the inter-
face is awaiting data from the Central (IP) and/or Remote sites (serial).
(Transparent mode)
Steady:
Unbalanced mode: Data has been received from the Central site and sent to the
Remote site (serial). Awaiting a response from the Remote site. (Non-transparent
mode)
Balanced mode: Data has been received from the Central site and sent to the Re-
mote site (serial). Awaiting a response from the Remote site. Alternatively, data
has been received from the Remote site and sent to the Central site (IP). Awaiting
a response from the Central site. (Non-transparent mode)
Flashing: Data is being transferred through the serial interface. (For all modes).
The serial interface has not been detected/installed or is configured as DOWN.
The serial interface is detected and the Control signal is inactive.