Teldat S.A.
power (in the DC or DC-powered MR models).
Power Supply Connector Detail
Fig. 9:
4.1.1.1 DC-Powered Device
PIN
-
+
4.1.1.2 AC-Powered Device
PIN
N
L
4.1.2 Power Connector Cable
Warning
The router does not include a power cable. You may use any power cable with a conductor gauge of
0.75 mm2 (AWG18) or larger, provided it is IEC 60227 certified.
Warning
All AC-powered interconnected communication devices must be connected to the SAME GROUNDED
POWER OUTLET. The power outlet should be of high quality with a resistance of less than 10 ohms.
For DC-powered models, the power distribution system must be confined to a single building and
grounded at a single point. This grounding requirement may be waived if the cabling for the DC power
distribution system is less than 4 meters long or fully enclosed in a metal conduit.
It is strongly advised to connect all data devices to the same power source, regardless of whether the
workplace is equipped with an Uninterruptible Power Supply (UPS), a regulated power supply, or oper-
ates independently from other systems (such as lighting). This practice helps to avoid malfunctions and
premature wear of drivers and other components.
Regesta Smart PRO
Signal
- V DC
+ V DC
Signal
Neutral
Phase
4 Connecting the Router
21
Need help?
Do you have a question about the Regesta Smart PRO and is the answer not in the manual?