D.1.10 Fibre Channel Sequence Example
FCP Information Unit
Sending all data with one FCP_DATA:
Initiator IU
FCP_CMND
Sending all data dividing them into two or more FCP_DATAs:
Initiator IU
FCP_CMND
318
Appendix D Interfaces
Direction
---------------------------------->
<----------------------------------
<----------------------------------
<----------------------------------
Direction
---------------------------------->
<----------------------------------
<----------------------------------
<----------------------------------
<----------------------------------
<----------------------------------
<----------------------------------
<----------------------------------
Target IU
FCP_XFER_READY
FCP_DATA
FCP_RSP
Target IU
FCP_XFER_READY
FCP_DATA
FCP_XFER_READY
FCP_DATA
FCP_XFER_READY
FCP_DATA
FCP_RSP