Table 2.10
Input Power and Insulation Performance Specifications for the Floor Model
Item
Model
Input power
Input voltage (V)
specification
Frequency (Hz)
Number of phases,
cabling
Steady-state current (A)
(Note 1) (Note 2)
Breaking current (A)
Required
power
Heat value (kJ/h)
Insulation
Insulation withstand
voltage
performance
Insulation resistance
Note1: Power current of Nx2 described above is required for operation by a single power supply unit.
Note2: The current value in the operation by a single power supply unit is same as that in the operation by both power
supply units.
Table 2.11
Input Power and Insulation Performance Specifications for the NAS Unit
Item
Input power
Input voltage (V)
specification
Frequency (Hz)
Number of phases, cabling
Steady-state current (A)
Breaking current (A)
Required
power
Heat value (kJ/h)
Insulation
Insulation withstand
performance
voltage
Insulation resistance
Floor (RKS+H1J) Model
AC 100/200 (100-120/200-240)
50/60 ± 1
Single-phase with protective grounding
4.0×2/2.0×2
16.0
Steady state
800 or less
(VA)
Starting
800 or less
state (VA)
2,880 or less
AC 1,500 V (10 mA, 1 min)
DC 500 V, 10 M Ω or more
Model
RKNAS
AC 100/200 (100-120/200-240)
50/60 ± 1
Single-phase with protective grounding
2.0/1.4
10.0
Steady state
280 or less
(VA)
Starting state
280 or less
(VA)
1,010 or less
AC 1,500 V (10 mA, 1 min)
DC 500 V, 10 M Ω or more
Acer | HDS AMS200 User and Reference Guide
Floor Model
Floor (RKS+RKAJ+H2J) Model
4.0×2+2.6×2/2.0×2+1.3×2
1,320 or less
1,360 or less
4,755 or less
33