D.1.7 FCP
Frame Format
AMS200 supports the six Information Units (IU) shown in the following table.
Table D.10 Information Unit
No.
Name
1
FCP_CMND
2
FCP_XFER_READY
3
FCP_DATA
4
FCP_RSP
5
FCP_CMND+FCP_DATA
6
FCP_DATA+FCP_RSP
The format of the standard frame header used in the FCP is shown in Table D.11.
Table D.11 Frame Header Format
Bits/Word
31 to 24
0
R_CTL
1
Reserved
2
TYPE
3
SEQ_ID
4
OX_ID
5
RLTV_OFF
R_CTL (Routing control):
This is used to identify the information category of the FCP frame.
1: FCP_DATA (Data In action, Data Out action).
5: FCP_XFER_RDY (Data delivery request).
6: FCP_CMND (Command/Task Management Request).
7: FCP_RSP (Command/Task Management Response).
Meaning
Transfers SCSI Command or Task Management
Notifies FCP_DATA will be transferred.
Transfers Data.
Transfers Status Information
Transfers SCSI Command and the first Data within a single
Information Unit. (Write Type Command)
Transfers last Data and the Status Information within a single
Information Unit. (Read Type Command)
23 to 16
15 to 08
D_ID
S_ID
F_CTL
DF_CTL
SEQ_CNT
RX_ID
07 to 00