Table 7.2 Formatting Message; Status Displays - Acer HDS AMS200 Reference Manual

Acer hds ams200 server: reference guide
Table of Contents

Advertisement

(NAS)
To confirm the latest progress rate, refresh the display by clicking Refresh.
3. Normal displays in the Status box. (When the formatting is in execution, the progress

status displays.)

If formatting is terminated abnormally, review the results.
The formatted logical information is updated and the window displays.
Table 7.2
Formatting Message
Displayed
02-xxxx, 03-xxxx, 04-xxxx or 0B-xxxx
05-xxxx
05-2500 or 05-2581
05-2600
05-2580
0B-FD01
DMEA000006 or DMEA000007
Action to be Taken
For the above code, a hardware fault is assumed. If the fault is not recovered
after re-execution, contact Acer | HDS.
For the above code, an operation error is assumed. Upon checking the
following items and re-execute processing. If the error is not recovered,
contact Acer | HDS.
Is logical unit 0 defined?
In spite of none of drive mounted states, is ALL RAID specified and is a
logical unit specified for ALL CAPA formatted?
Is an attempt made to define a logical unit exceeding the capacity of the
defined RAID group?
Switching a controller in charge of a logical unit occurred during formatting.
Check the controller in charge and re-execute formatting from the controller
in charge.
Drive failure recovery or ShadowImage-In-System Replication, TrueCopy
Synchronous Remote Replication, and/or Copy-on-Write Snapshot may be in
operation. Check the status of the subsystem.
Acer | HDS AMS200 User and Reference Guide
149