Advertisement

Parameters
Characters
ol-h
MV Upper Limit
(See note 1.)
ol-l
MV Lower Limit
(See note 1.)
orl
MV Change Rate
Limit
db
Position Propor-
tional Dead Band
oc-h
Open/Close Hystere-
sis
sgrp
Extraction of Square
Root Low-cut Point
Note
(1) The parameters in the current PID set will be accessed.
(2) The parameters in the current bank will be accessed.
(3) Not displayed for heating/cooling control or floating control (for models with position-proportional
control).
314
Setting (monitor) value
Standard: MV lower limit (0.1
to 105.0
Heating/cooling: 0.0 to 105.0
Position proportional (closed):
MV upper limit (0.1 to 105.0)
Standard: −5.0 to MV upper
limit −0.1
Heating/cooling: −105.0 to 0.0
Position proportional (closed):
−5.0 to MV upper limit −0.1
0.0 to 100.0
(0.0: MV Change Rate Limit
Disabled)
Position proportional (closed):
0.1 to 10.0
Position proportional
(floating): 0.1 to 10.0
0.1 to 20.0
0.0 to 100.0
Display
Default
105.0
%
−5.0
%
−105.0
−5.0
0.0
%/s
4.0
%
2.0
0.8
%
0.0
%
Appendix
Unit
Set value