Omron E5EC-T Datasheet
Omron E5EC-T Datasheet

Omron E5EC-T Datasheet

Programmable temperature controller
Hide thumbs Also See for E5EC-T:

Advertisement

Quick Links

Programmable Temperature Controller (Digital Controller)
E5EC-T/E5AC-T
Programmable Controllers Join the E5 C Series!
Program up to 256 segments can handle a
wide variety of applications.
• Set up to 8 Programs (Patterns) with 32 Segments (Steps) Each
• A white LCD PV display with a height of approx. 18 mm for the E5EC-
T and 25 mm for the E5AC-T improves visibility.
• Tool ports are provided both on the top panel and the front panel. Set
up the Controller without wiring the power supply by connecting to the
computer with a Communications Conversion Cable (sold
separately). Setup is easy with the CX-Thermo (sold separately).
• High-speed sampling at 50 ms.
• Models are available with up to 4 auxiliary outputs, up to 6 event
inputs, and a transfer output to cover a wide range of applications.
• Short body with depth of only 60 mm.
• Easy connections to a PLC with programless communications. Use
component communications to link Temperature Controllers to each
other.
• The new position-proportional control models allow you to control
valves as well. (The position-proportional control models are
scheduled to be released in May, 2014.)
Main I/O Functions
Sensor Input
Universal input
• Thermocouple
• Pt
• Analog current/voltage
Indication Accuracy
• Thermocouple input: ±0.3% of PV
• Pt input: ±0.2% of PV
• Analog input: ±0.2% of FS
Sampling Period
• 50 ms
Event Inputs
• None
• 2
• 4
• 6
Serial Communications
• None
• RS-485
This datasheet is provided as a guideline for selecting products.
Be sure to refer to the following manuals for application precautions and other information required for operation before attempting
to use the product.
E5@C-T Digital Temperature Controllers Programmable Type User's Manual (Cat. No. H185)
E5@C-T Digital Temperature Controllers Programmable Type Communications Manual (Cat. No. H186)
E5EC-T
E5AC-T
• PF (shift) Key
• Setup Tool port on front panel
• Temperature status display
• Operating and editting the program
• Independent heating and
cooling PID control
• Parameter mask setting
• Display brightness setting
(48 × 96 mm/96 × 96 mm)
48 × 96 mm
E5EC-T
Refer to your OMRON website for the most recent
information on applicable safety standards.
Refer to Safety Precautions on page 104.
Three-level Display
Simultaneous display of the PV, SP,
Program No., Segment No., etc.
Control Output 1
• Relay output
• Voltage output (for driving SSR)
• Linear current output
Control Output 2
• Voltage output (for driving SSR)
• Relay output
• Linear current output
Auxiliary Outputs
• 4
Transfer Output
• None
• 1
96 × 96 mm
E5AC-T
4-digit
displays
1

Advertisement

Table of Contents
loading

Summary of Contents for Omron E5EC-T

  • Page 1 • Short body with depth of only 60 mm. Refer to your OMRON website for the most recent information on applicable safety standards. • Easy connections to a PLC with programless communications. Use component communications to link Temperature Controllers to each Refer to Safety Precautions on page 104.
  • Page 2: Heating And Cooling Control

    E5EC-T/E5AC-T Model Number Legend and Standard Models Model Number Legend ●Models with Screw Terminals E5EC-T@@ 4 @ 5 M -@@@ (Example: E5EC-TRX4A5M-000) −−− − − − −−− A B C D E E5AC-T@@ 4 @ 5 M -@@@ (Example: E5AC-TRX4A5M-000) −−−−...
  • Page 3 EST2-2C-MV4 Note: Always use this product together with the E58-CIFQ2. This Cable is used to connect to the front-panel Setup Tool Note: CX-Thermo version 4.61 or higher is required for the E5EC-T/ port. E5AC-T. For the system requirements for the CX-Thermo, refer to...
  • Page 4: Specifications

    Digital setting using front panel keys 11-segment digital display and individual indicators Character height: E5EC-T: PV: 18.0 mm, SV: 11.0 mm, MV: 7.8 mm E5AC-T: PV: 25.0 mm, SV: 15.0 mm, MV: 9.5 mm Indication method Three displays. Contents: PV, SP, program No. and segment No., remaining segment time, or MV...
  • Page 5: Input Ranges

    E5EC-T/E5AC-T Input Ranges ●Thermocouple/Platinum Resistance Thermometer (Universal inputs) Sensor Platinum resistance Infrared temperature Thermocouple type thermometer sensor Sensor 10 to 60 to 115 to 140 to specifica- Pt100 JPt100 PLII 70°C 120°C 165°C 260°C tion 2300 2300 1800 1800 1700...
  • Page 6: Alarm Types

    E5EC-T/E5AC-T Alarm Types Each alarm can be independently set to one of the following 17 alarm types. The default is 2: Upper limit. (see note.) Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also be specified.
  • Page 7 E5EC-T/E5AC-T With set values 1, 4 and 5, the upper and lower limit values can be set Set value: 5, Upper- and lower-limit with standby sequence independently for each alarm type, and are expressed as “L” and “H.” For Upper- and Lower-Limit Alarm Described Above *2 Set value: 1, Upper- and lower-limit alarm •...
  • Page 8 Non-volatile memory (number of writes: 1,000,000 times) Setup Tool CX-Thermo version 4.61 or higher E5EC-T/E5AC-T top panel: An E58-CIFQ2 USB-Serial Conversion Cable is used to connect to a USB port on the computer.*5 Setup Tool port E5EC-T/E5AC-T front panel: An E58-CIFQ2 USB-Serial Conversion Cable and E58-CIFQ2-E Conver- sion Cable are used together to connect to a USB port on the computer.*5...
  • Page 9: Program Control

    E5EC-T/E5AC-T Program Control Number of programs (patterns) Number of segments (steps) Time setting (Segment set with set point and time.) Segment setting method Slope setting (Segment set with segment type, set point, slope, and time.) 0 h 0 min to 99 h 59 min...
  • Page 10: Communications Specifications

    E5EC-T/E5AC-T USB-Serial Conversion Cable When Digital Temperature Controllers are con- nected, set points and RUN/STOP commands can be sent from the Digital Temperature Control- Applicable OS Windows XP/Vista/7/8 Component ler that is set as the master to the Digital Temper- Applicable software CX-Thermo version 4.61 or higher...
  • Page 11: External Connections

    E5EC-T/E5AC-T External Connections E5EC-T/E5AC-T E5EC E5AC (2) (3) (4) (5) (2) (3) (4) (5) Terminal type Terminal type Control output 1 Control output 2 Auxiliary outputs Relay output Relay output Relay output Models with 4 auxiliary 250 VAC, 5 A...
  • Page 12 E5EC-T/E5AC-T Nomenclature E5EC-T Front panel Top View of E5EC-T No. 1 display Temperature unit PV or specified monitor/parameter Operation indicators No. 2 display Top-panel Setup SP or specified monitor/parameter value Tool port No. 3 display Use S Key to change the Program No., segment No.,...
  • Page 13 E5EC-T/E5AC-T Dimensions (Unit: mm) Controllers E5EC-T (64) The Setup Tool ports are on the front and top of the Digital Temperature Controller. It is used to connect the Temperature Con- troller to the computer to use the Setup Tool. The E58-CIFQ2 USB-Serial Conversion Cable is required to make the connection.
  • Page 14: Conversion Cable

    E5EC-T/E5AC-T E5AC-T (64) 96 x 96 91 x 91 Waterproof Packing (Accessory) Mounting Adapter (Accessory) The Setup Tool ports are on the front and top of the Digital Temperature Controller. It is used to connect the Temperature Controller to the computer to use the Setup Tool.
  • Page 15 The degree of protection when the Waterproof Packing is used is IP66. Also, keep the Port Cover on the front-panel Setup Tool port of the E5EC-T/E5AC-T securely closed. To maintain an IP66 degree of protection, the Waterproof Packing and the Port Cover for the front-panel Setup Tool port must be periodically replaced because they may deteriorate, shrink, or harden depending on the operating environment.
  • Page 16: Current Transformers

    Thru-current (Io) vs. Output Voltage (Eo) (Reference Values) Two, M3 (depth: 4) E54-CT3 Maximum continuous heater current: 120 A (50/60 Hz) (Maximum continuous heater current for an OMRON Digital Temperature Controller is 50 A.) ± Number of windings: ± Ω...
  • Page 17 E5EC-T/E5AC-T E5 C-T This diagram shows all of the setting levels. To move to the advanced function setting level and calibration level, you must enter passwords. Some parameters are not displayed depending on the protect level setting and the conditions of use.
  • Page 18: Monitor/Setting Item Level

    E5EC-T/E5AC-T E5@C-T Some parameters may not be displayed depending on the model and other settings. Starting in manual mode Monitor/Setting Item Level PF Monitor/ Power ON PF Monitor/Setting Manual Control Level Setting Item Item display 2 to 5 display 1...
  • Page 19 E5EC-T/E5AC-T Press O Key Protect Level for at least 1 s. Press O + M Key for at least 3 s. Operation/Adjustment pmov oapt pfpt PF Key Protect Protect Move to Protect Level Initial Setting/ Parameter Mask Enable icpt pmsk Press O + M Key for at least 3 s.
  • Page 20: Advanced Function Setting Level

    E5EC-T/E5AC-T Advanced Function Setting Level Direct Setting of Position init mant pmvd Manual Output Method Proportional MV Parameter Initialization hold PV Rate of Change mani pvrp pend Manual MV Initial Value Program End ON Time Calculation Period hctm Heating/Cooling Tuning...
  • Page 21 E5EC-T/E5AC-T Error Displays (Troubleshooting) When an error occurs, the No. 1 display or No. 2 display shows the error code. Take necessary measure according to the error code, referring the following table. Display Name Meaning Action Operation After the error occurs and it is...
  • Page 22: Safety Precautions

    E5EC-T/E5AC-T Safety Precautions ● Be sure to read the precautions for all E5@C/E5@C-T models in the website at: http://www.ia.omron.com/. Warning Indications Minor electric shock or fire may occasionally occur. Indicates a potentially hazardous Do not use any cables that are damaged.
  • Page 23: Precautions For Safe Use

    E5EC-T/E5AC-T Precautions for Safe Use Be sure to observe the following precautions to prevent malfunction generate noise (in particular, motors, transformers, solenoids, magnetic coils, or other equipment that have an inductance or adverse affects on the performance or functionality of the product.
  • Page 24: Service Life

    Keep the Port Cover on the front-panel disconnecting the Main Unit, do not allow the electronic Setup Tool port of the E5EC/E5AC/E5EC-T/E5AC-T securely closed. components to touch the case. The degree of protection when the Waterproof Packing is used is 35.Observe the following precautions when you remove the terminal...
  • Page 25 Waterproof packing is not necessary when there is no need for the attach it to the terminal block. waterproofing function. 2. Insert the E5EC/E5AC/E5EC-T/E5AC-T into the mounting hole in the panel. 3. Push the adapter from the terminals up to the panel, and temporarily fasten the E5EC/E5AC/E5EC-T/E5AC-T.
  • Page 26: Precautions When Wiring

    Unit are short-circuited, and the ambient temperature is stable. Should the Unit malfunction during the guarantee period, OMRON shall repair the Unit or replace any parts of the Unit at the expense of...
  • Page 27: Terms And Conditions Of Sale

    Buyer indemnifies Omron against all related costs or expenses. rights of another party. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery 16. Property; Confidentiality. Any intellectual property in the Products is the exclu-...
  • Page 28 OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br OMRON EUROPE B.V. • Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. • +31 (0) 23 568 13 00 • www.industrial.omron.eu Authorized Distributor: Automation Control Systems •...

This manual is also suitable for:

E5ac-t

Table of Contents