Omron E5AN-H Datasheet
Omron E5AN-H Datasheet

Omron E5AN-H Datasheet

Advanced digital temperature controller
Hide thumbs Also See for E5AN-H:

Advertisement

Quick Links

Advanced Digital Temperature Controller
E5AN-H/E5EN-H
A New High-performance Controller:
High Resolution, High Speed, and High Input Accuracy.
With Logic Operations and preventive maintenance functions.
Plus Infrared Port on Front Panel.
• High-resolution display with 5 digits/0.01°C display.
• High-speed sampling cycle of 60 ms.
• High Accuracy
Thermocouple/Pt input: ±0.1% of PV
Analog input: ±0.1% FS
• Universal inputs on all models (thermocouple, PT, analog) to
handle various sensors with one Controller. Models also available
with Remote SP.
• A PV/SV-status display function can be set to displaying
the PV or SV and the status of the Temperature Controller
(auto/manual, RUN/STOP and alarms).
• Flexible contact outputs with logic operations (AND, OR, and
delays) set from the Support Software (CX-Thermo Ver. 4.0)
• Preventive maintenance for relays using a Control Output ON/OFF
Counter.
• Model available with position-proportional control
Main I/O Functions
Remote SP Input
Event Inputs
• None
• Two
• Four
Universal Sensor Inputs
• Universal thermocouple/
Pt/analog
(current/voltage) inputs.
Indication Accuracy
• Thermocouple/Pt input:
±0.1% of PV
• Analog input:
±0.1% FS
Sampling Period and control
update
• 60 ms
PF Key
(Programmable
key function)
E5AN-H
E5EN-H
Infrared port
USB
Control Output 2
(built-in)
Output Unit
• SSR outputs
• Relay output
• Voltage output (for driving SSR)
• Current output
• Linear voltage output
Control Output 1
(built-in)
Output Unit
• SSR outputs
• Relay output
• Voltage output (for driving SSR)
• Current output
• Linear voltage output
Advanced Digital Temperature Controller
(96 x 96 mm and 48 x 96 mm)
96 × 96 mm
E5AN-H
Refer to Safety Precautions on page 22.
3-line Display
Simultaneously displays set items, such as the
PV, SV, and MV.
5-digit, 11 segment display with high resolution of 0.01°C
Auxiliary Outputs
• Two
• Three
Computer Support Software
CX-Thermo
E5AN-H/E5EN-H
48 × 96 mm
E5EN-H
• Auto/manual switching
• Temperature Controller
status display
• Simple program
function
• Logic operations
• Control output ON/OFF
count alarm
• PV change rate alarm
• Models optional with
RS-485 or RS-232C
communications
1

Advertisement

Table of Contents
loading

Summary of Contents for Omron E5AN-H

  • Page 1 Controller. Models also available with Remote SP. • A PV/SV-status display function can be set to displaying the PV or SV and the status of the Temperature Controller (auto/manual, RUN/STOP and alarms). • Flexible contact outputs with logic operations (AND, OR, and 96 ×...
  • Page 2: Model Number Structure

    Note: Casing color is black. White/Silver available on request. This data sheet is provided as a guideline for selecting products. Be sure to refer to the following user manuals for application precautions and other information required for operation before attempting to use the product.
  • Page 3: Ordering Information

    Note: Add power supply voltage to model to complete ordering code (ie. E5AN-HAA2HBM-500 AC100-240 or E5AN-HAA2HBMD-500 AC/DC24) Note: Heater alarm = heater burnout + SSR short detection + SSR overcurrent Note: For output option modules (AA), see “output modules E53-_ N“ on page 2 E5AN-H/E5EN-H Advanced Digital Temperature Controller...
  • Page 4 E5EN-HPRR2BFMD-500 output input Note: Add power supply voltage to model to complete ordering code (ie. E5EN-HAA2HBM-500 AC100-240 or E5EN-HAA2HBMD-500 AC/DC24 Note: Heater alarm = heater burnout + SSR short detection + SSR overcurrent Note: For output option modules (AA), see "output modules E53-_ N" on page 2...
  • Page 5: Specifications

    Any of the following four patterns can be selected. The input status may be inverted. (A and B) or (C and D), (A or C) and (B or D), A or B or C or D, A and B and C and D (A, B, C, and D are four inputs.)
  • Page 6: Input Ranges

    Shaded settings are the default settings. The applicable standards for the input types are as follows: K, J, T, E, N, R, S, B: JIS C 1602-1995, IEC 584-1 JPt100: JIS C 1604-1989, JIS C 1606-1989 L: Fe-CuNi, DIN 43710-1985...
  • Page 7: Alarm Outputs

    Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also be specified. Note: For models with heater burnout, SSR failure, and heater overcurrent detection, alarm 1 will be an OR output of the alarm selected from the following alarm types and the alarms for heater burnout, SSR failure, and heater overcurrent.
  • Page 8 400°C max. is not specified. The indication accuracy of B thermocouples in the 400 to 800°C range is ±3°C max. The indication accuracy of the R and S thermocouples at a temperature of 200°C max. is ±3°C ±1 digit max. The indication accuracy of W thermocouples is ±0.3% of PV or ±3°C, whichever is greater, ±1 digit max.
  • Page 9: Communications Specifications

    ✽2. For SSR failure alarms, the heater current will be measured when the control output is OFF, and the output assigned to the alarm 1 function will turn ON if the heater current is higher than the set value (i.e., SSR failure detection current value).
  • Page 10 • Rated load voltage: 75 to 250 VAC • Rated load current: 1 A (resistive load) Note: 1. The load current must be within the derating curve. 2. There is no zero-cross function. Derating Curve for SSR Outputs (Reference Values)
  • Page 11: External Connections

    • A voltage output (control output 1, for driving SSR) is not electrically insulated from the internal circuits. When using a grounding thermocouple, do not connect any of the control output terminals to ground. If the control output terminals are connected to ground, errors will occur in the measured temperature values as a result of leakage current.
  • Page 12 96 × 96 in the specifications. ✽ Group mounting is not possible if an SSR output is used for control output 1 or 2 and the E53-C3N or E53-C3DN Output Unit is used. For these combinations, maintain the following mounting space between Controllers.
  • Page 13 ✽ Group mounting is not possible if an SSR output is used for control output 1 or 2 and the E53-C3N or E53-C3DN Output Unit is used. For these combinations, maintain the following mounting space between Controllers.
  • Page 14 Accessories (Order Separately) USB-Infrared Conversion Cable E58-CIFIR USB-Infrared Conversion Cable (2,000) 35.8 4.6 dia. USB connector (type A plug) LED indicator: RD LED indicator: SD 17.8 With Mounting Adapter Connected Mounting Adapter 18.5 Mounting Adapter (Accessory) 99.2 23.1 21.8 (75)
  • Page 15: Current Transformers

    Y92S-P4 (for DIN 96 × 96) Order the Waterproof Packing separately if it becomes lost or damaged. The Waterproof Packing can be used to achieve an IP66 degree of protection. (Deterioration, shrinking, or hardening of the waterproof packing may occur depending on the operating environment. Therefore, periodic replacement is recommended to ensure the level of waterproofing specified in IP66.
  • Page 16 E5AN-H/E5EN-H Advanced Digital Temperature Controller...
  • Page 17: Operation

    ✽5. When the PF Setting parameter is set to PFDP for a Controller with a PF Key (E5AN-H/E5EN-H) Error Displays (Troubleshooting) When an error occurs, the No.1 display shows the error code. Take necessary measure according to the error code, referring the table below. Status at error No.1 display...
  • Page 18: Pid Setting Level

    E5EN-H / E5AN-H Some parameters are not displayed depending on the model of the Controller and parameter settings. For details, refer to the E5CN-H/E5AN-H/ Power ON E5EN-H Digital Controllers User's Manual Advanced Type (Cat. No. H157). Manual Control Level Operation...
  • Page 19: Manual Control Level

    ✽2 PF Key ✽1. When the PF Setting parameter is set to A-M for a Controller with a PF Key (E5AN-H/E5EN-H). ✽2. When the PF Setting parameter is set to PFDP for a Controller with a PF Key (E5AN-H/E5EN-H). E5AN-H/E5EN-H...
  • Page 20: Initial Setting Level

    The time taken to move to the protect level Displayed only for models with communications. Changes can be adjusted by changing the "Move to are effective after cycling power or after a software reset. protect level time" setting. in-h Scaling Upper Limit...
  • Page 21: Advanced Function Setting Level

    Level Level Communica- Initial Setting tions Setting Level Level Advanced Function Setting Level Press the O Key for at least 1 s. Advanced Function Setting Level pfd1 Input Shift Type alsp Alarm SP Selection istp o-dp MV Display init Parameter Initialization...
  • Page 22: Safety Precautions

    30 V r.m.s. and 42.4 V peak or 60 VDC. connected to the product. Malfunction may occur due to ✽2. A class 2 power supply is one tested and certified by UL as having noise in the cable. the current and voltage of the secondary output restricted to specific levels.
  • Page 23: Measurement Accuracy

    3. Mount the product so that it is horizontally level. use RAM write mode when frequently overwriting data during 4. If the measurement accuracy is low, check to see if input shift has communications or other operations. been set correctly.
  • Page 24: Precautions When Wiring

    2. Insert the flat-blade screwdriver in the gap between the front panel and rear case (two on the top and two on the bottom), and use it to pry and pull out the front panel slightly. Then, pull out on the front panel gripping both sides.
  • Page 25 E5@N/E5@N-H Advanced Digital Temperature Controller...
  • Page 26: Warranty And Application Considerations

    CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE...

This manual is also suitable for:

E5en-h

Table of Contents