CLEARPOINT
3eco
®
Connection [inches]
Volume flow at 7 bar(g) 
energy-optimised [m³/h]
*1
Differential 
pressure [mbar]
(wet saturated)
Volume flow at 7 bar(g) 
performance-oriented [m³/h]
Differential 
pressure [mbar]
(wet saturated)
Category according to
PED 2014/68/EU
Min. / max. operating pressure
[bar(g)]
Min. / max. operating temperature
[°C]
Load test according to AD2000
Medium
Weight [kg]
Volume [l]
 Volume flow at 7 bar(g) referring to +20 °C and 1 bar(abs)
*1
S040
S050
3/8
1/2
35
CX
FX
80
115
SX
100
125
46
*1
CX
FX
105
160
SX
125
170
-
10000 load changes ≙ pressure difference ≥3.2 bar at 16 bar(g)
Compressed gases of fluid group 2 according to PED 2014/68/EU
0.75
0.85
0.25
0.31
S055
S075
1/2
3/4
65
100
150
Ø 50
150
105
170
120
85
130
195
Ø 70
230
150
255
175
-
-
-
0 ... 16
+2 ... +60
free of aggressive and corrosive components
1.2
1.7
0.42
0.87
CLEARPOINT
3eco
coalescence filter
®
M010
M012
1
1
200
250
120
165
135
180
260
325
180
230
200
260
-
-
2.1
2.2
1.12
1.26
M015
1 1/2
320
80
100
415
110
130
-
4.1
2.52
21 | 56