Installation Diagrams - B&R PC 3100 User Manual

Panel mount device
Hide thumbs Also See for PC 3100:
Table of Contents

Advertisement

Technical data

4.1.3.2 Installation diagrams

Information:
When installing the Panel PC 3100, spacing for air circulation and additional free space for operating
and servicing the device must be taken into account.
The cutout tolerances are +0 mm / -0.5 mm.
AP9x3 panels
Type
12.1" single-touch
15.0" single-touch
19.0" single-touch
15.6" multi-touch
18.5" multi-touch
21.5" multi-touch
24.0" multi-touch
Dimension "Z" describes the thickness of the wall or control cabinet plate.
A hex screwdriver is needed to tighten and loosen the screw on the retaining clips. The maximum tightening torque
of the retaining clips is 1 Nm.
32
X
Model number
5AP923.1215-00
5AP923.1505-00
5AP923.1906-00
5AP933.156B-00
5AP933.185B-00
5AP933.215C-00
5AP933.240C-00
Panels
X
Y
Z min.
Z max.
304
228
1
6
359
277
1
6
429
347
1
6
403
247.5
1
6
464
284
1
6
530.5
322
1
6
587.5
353
1
6