Technical data

4.2.7.16 5ACCIF04.FPLK-000

4.2.7.16.1 General information
Interface option 5ACCIF04.FPLK-000 is equipped with a POWERLINK interface.
• 1x POWERLINK interface (managing or controlled node) for real-time communication
• Poll-response chaining
• Compatible with APC3100/PPC3100
• Easy installation in slot IF option 3.
• Support in Automation Runtime and Automation Studio: Both starting with V4.9
Simultaneous operation with another POWERLINK interface card (see
different addressing is possible. This allows parallel data acquisition from two separate networks.
With poll-response chaining (PRC), the IF option offers a solution for the highest demands on response time and
the shortest cycle times. When combined with the B&R control system, poll-response chaining provides ideal
performance, particularly for central control tasks.
This interface option can only be operated in the IF option 3 slot and is only supported by Automation Runtime.
4.2.7.16.2 Order data
Order number
Short description
Interface options
5ACCIF04.FPLK-000
Interface card - 1x POWERLINK interface - For APC3100/
PPC3100
4.2.7.16.3 Technical data
Information:
The following specified characteristic data, features and limit values are only valid for these individual
components and may differ from those of the complete system. The data specified for the complete
system applies to the complete system in which this individual component is used, for example.
Order number
General information
B&R ID code
Diagnostics
Data transfer
Certifications
CE
UKCA
UL
Interfaces
POWERLINK
Quantity
Type
Variant
Transfer rate
Transfer
Line length
Electrical properties
Power consumption
Operating conditions
Pollution degree per EN 61131-2
Ambient conditions
Temperature
Operation
Storage
Transport
186
IF option 2
5ACCIF04.FPLK-000
0xFC5E
Yes, using LED status indicator
Yes
Yes
cULus E115267
Industrial control equipment
1
Type 4
1)
RJ45, shielded
100 Mbit/s
100BASE-TX
Max. 100 m between two stations (segment length)
1.5 W
Pollution degree 2
0 to 55 °C
-20 to 60°C
-20 to 60°C
Panel PC 3100 panel mount device User's manual V 2.10