4.2.7.6 5AC901.ISRM-00

4.2.7.6.1 General information
Interface option 5AC901.ISRM-00 is equipped with 2 MB SRAM.
• 2 MB SRAM
• Compatible with APC910/PPC900 and APC3100/PPC3100
This interface option can only be operated in slot IF option 2.
4.2.7.6.2 Order data
Order number
Short description
Interface options
5AC901.ISRM-00
Interface card - 2 MB SRAM - For APC910/PPC900/APC3100/
PPC3100
4.2.7.6.3 Technical data
Information:
The following specified characteristic data, features and limit values are only valid for this accessory
and may differ from those of the complete system. The data specified for the complete system applies
to the complete system in which this accessory is installed, for example.
Order number
General information
B&R ID code
Certifications
CE
UKCA
UL
HazLoc
EAC
Controller
SRAM
Size
Battery-backed
Remanent variables in power failure mode
Electrical properties
Power consumption
Operating conditions
Pollution degree per EN 61131-2
Ambient conditions
Temperature
Operation
Storage
Transport
Relative humidity
Operation
Storage
Transport
Mechanical properties
Weight
1)
Yes, but applies only if all components installed in the complete system have this certification and the complete system bears the corresponding mark.
2)
For detailed information, see the temperature tables in the user's manual.
Panel PC 3100 panel mount device User's manual V 2.10
5AC901.ISRM-00
0xD850
Yes
Yes
cULus E115267
Industrial control equipment
cULus HazLoc E180196
Industrial control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T4
Product family certification
2 MB
Yes
256 kB (for e.g. Automation Runtime, see Automation Help)
2 W
Pollution degree 2
0 to 55°C
-20 to 60°C
-20 to 60°C
5 to 90%, non-condensing
5 to 95%, non-condensing
5 to 95%, non-condensing
Approx. 20 g