7.6.4 Automation Runtime

7.6.4.1 General information

The real-time operating system Automation Runtime is an integral part of Automation Studio. This real-time oper-
ating system forms the software core for running applications on a target system.
• Guarantees the highest possible performance of the hardware being used
• Runs on all B&R target systems
• Makes the application hardware-independent
• Easy portability of applications between B&R target systems
• Guaranteed determinism through cyclic system
• Configurable jitter tolerance in all task classes
• Support for all relevant programming languages, such as IEC 61131-3 languages and C
• Rich function library per IEC 61131-3 as well as the extended B&R automation library
• Integrated in Automation NET. Access to all networks and bus systems via function calls or by configuration
in Automation Studio
B&R Automation Runtime is fully embedded in the corresponding target system (hardware on which Automation
Runtime is installed). It thus enables application programs to access I/O systems (also via the fieldbus) and other
devices such as interfaces and networks.

7.6.4.2 Minimum versions

7.6.4.2.1 Automation Runtime Embedded (ARemb)
System requirements
The following software versions (or higher) are required to operate Automation Runtime Embedded on a Panel
PC 3100:
• ARemb upgrade AR E4.34
• Automation Studio V4.3.4
• Visual Components Runtime (VC) V4.34
• Automation software license (TG or TC)
Information:
In order to use Automation Runtime Embedded (ARemb), BIOS setting Advanced - OEM features -
Realtime environment must be set to Enabled.
7.6.4.2.2 Automation Runtime Windows (ARwin)
System requirements
The following software versions (or higher) are required to operate Automation Runtime Windows on a Panel PC
3100:
• ARwin Upgrade AR E4.34
• Automation Studio V4.3.4
• Technology Guard
Information:
To operate Automation Runtime Windows (ARwin), parameter Advanced - OEM features - Realtime
environment must be set to Enabled in BIOS and parameter Boot - EFI device first must be set to
Disabled.
Information:
ARwin is no longer supported starting with Automation Runtime V4.6.
Information:
For detailed information, see Automation Help or the B&R website (www.br-automation.com).