3.5.6

AC charging socket

The optional AC charging socket is located below the credit card reader and RFID reader. The
cover prevents the ingress of dust and moisture. The integrated shutter is a mechanical
protection measure for personal safety. The shutter ensures that the power contacts cannot
come into contact with fingers or objects.
Figure 3-4  AC charging socket with protective cap and integrated shutter
The charging socket is equipped with an actuator. The actuator locks the charging cable
before the start of the charging process and unlocks it again after the charging process. The
charging cable with Type 2 plug must be provided by the user. The charging cable must
support mode 3.
3.5.7

AC meter (charging outlet)

If the optional AC charging socket is installed, then an AC counter is also installed.
The window with the display of the AC meter is located below the viewing window of the DC
meter. The AC meter shows the amount of energy emitted by the AC charging socket. For
information about the contents displayed, refer to the operating instructions of the AC meter
you are using. You can find the type of device used in the bill of materials of your charging
station.
3.5.8

DC meters

The window with the display of the DC meters of the respective charging point is located
below the plug holder. The amount of energy supplied can be read on the DC meter. For
information about the contents displayed, refer to the operating instructions of the DC meter
you are using. You can find the type of device used in the BOM of your charging station.