5.5.3

Inserting the cables into the cabinet

Open the device door and remove the protective cover of the conductor connections to the
circuit breaker. Pull the conductors through the opening in the cabinet floor.
Figure 5-9  Inserting the cable into the cabinet
5.5.4

Securing the charging station

After you have routed the cables into the cabinet, fasten the charging station on the base
area.
Required tools and fasteners
You will need the following tools to secure the charging station:
• Torque wrench
• Socket: Hexagon, SW18
The fastening material is not included in the scope of delivery.
We recommend the following fastening material:
• 4 nuts M12 DIN 934
• 4 spring lock washers M12
• 4 spring washers M12 DIN 125
• 4 fastening elements, for example: Bolt anchors M12
Securing the charging station
Use the four studs in the prepared base (Page 76) to secure the charging station. Use
washers, spring lock washers and nuts to secure the charging station. The tightening torque
for the bolt anchor is 70 Nm.