Switching Off The Charging Station; Restarting The Charging Station - Siemens SICHARGE D Operating Instructions Manual

Hide thumbs Also See for SICHARGE D:
Table of Contents

Advertisement

Commissioning

6.4 Restarting the charging station

Cold start function
To protect components, the controller checks whether the climatic conditions in the charging
station are permissible each time it boots up. If the temperature is too low or the air humidity
is too high, a heating fan is switched on initially, which ensures optimal climatic conditions
inside the charging station. This prevents possible damage, for example, due to
condensation.
The display, LED strips and other components remain switched off during this time. The
heating fan operation is audible at the front of the charging station. The charging station
resumes booting and the remaining components are switched on as soon as the climatic
conditions are okay.
This duration of this process depends on the actual conditions and can last up to 30 minutes.
Do not open the doors during this time, in order to avoid interrupting the process. Cold or
moist incoming air can further increase the duration.
6.3

Switching off the charging station

You can only shut down the charging station on site. If you open one of the two doors, then a
message appears on the touch screen that one door is open and two buttons appear on the
touch screen. The "Shutdown" button shuts down the charging station. When the touch
screen and the LED strips are off, you can activate the charging station via the upstream
switchgear.
The charging station is only turned off after shutdown. The supply voltage is still present in
the charging station. To activate the charging station, you must activate the upstream
switching device outside the charging station.
If you are working on the charging station, then observe The five safety rules for electrical
work (Page 20).
NOTE
Before activating the system, shut down the charging station using the procedure described.
6.4
Restarting the charging station
You can restart the charging station either on site or remotely via the SCB. If you open one of
the two doors, then a message appears on the touch screen that one door is open and two
buttons appear on the touch screen. The "Restart" button shuts down the charging station
and starts it up again automatically after a short waiting time.