Siemens SICHARGE CC AC22 Operating Manual
Hide thumbs Also See for SICHARGE CC AC22:

Advertisement

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SICHARGE CC AC22

  • Page 2 Introduction Safety information SICHARGE Description Operation SICHARGE CC AC22 - ERK SICHARGE Operating Manual ERK Faults Appendix Operating Manual List of abbreviations 07/2020 A5E48572458-AB...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Table Of Contents

    Table of contents Introduction ............................4 Purpose of this documentation .................... 4 Conventions ........................4 Open-source software ......................5 Safety information ..........................6 General safety information ....................6 Safety during operation and charging .................. 7 Description ............................. 9 Charging station structure....................9 Operation .............................
  • Page 5: Introduction

    Introduction Purpose of this documentation This operating manual contains information for operating the SICHARGE CC AC22 charging station. The operating manual contains information on the prescribed use of the charging station. WARNING Failure to comply with the information in these operating instructions may result in the following: •...
  • Page 6: Open-Source Software

    Siemens accepts no liability for the use of the open-source software over and above the intended program sequence, or for any faults caused by modifications to the software.
  • Page 7: Safety Information

    The following safety instructions are based on the utilization phases of the product life cycle. The operating manual is intended for drivers of electric vehicles who want to charge their vehicles with the SICHARGE CC AC22 charging station. Areas of application of the device •...
  • Page 8: Safety During Operation And Charging

    Safety information 2.2 Safety during operation and charging Safety during operation and charging The following description warns of additional hazards that must be considered when operating the charging station. Act according to the specified operating instructions, and observe the valid regional standards and regulations. Failure to follow safety instructions may result in hazardous situations that could cause death or serious injury.
  • Page 9 Safety information 2.2 Safety during operation and charging Charging cable and socket Defective connectors or cables may cause fire. Qualified personnel must shut down the unit and replace the damaged components immediately. Do not bend or squeeze the charging cable; do not run it over sharp edges, and use it only within the permissible temperature range.
  • Page 10: Description

    Description Charging station structure ① Status light ② RFID reader ③ Viewing window for meter ④ Charging connection type 2 ⑤ Pushbutton ⑥ Maintenance door Figure 3-1 Charging station structure SICHARGE Operating Manual ERK Operating Manual, 07/2020, A5E48572458-AB...
  • Page 11: Operation

    Status indicators Notes on operation The SICHARGE CC AC22 charging station is equipped with status indicators. Different colors and flashing signals indicate the current status of charging points 1 and 2. This signalizes to drivers if the charging station is available and what its status is.
  • Page 12 Operation 4.1 Status indicators Status indicators The following table provides an overview of status indicators of charging points: Does not light up If the status indicator does not light up, this indicates an interruption to the power supply. If there is not a power failure, check the backup fuses.
  • Page 13: Main Menu

    Operation 4.2 Main menu Main menu Symbols in the main menu When you switch on the charging station, you will see the following picture on the display. ① Charging station and connection status ② Display of instructions ③ Charging point indicator Figure 4-2 Main menu SICHARGE Operating Manual ERK...
  • Page 14 Operation 4.2 Main menu Table 4- 1 Symbols of the charging station and connection status Hardware fault Charging point status Charging station reserved Mobile network reception, network strength Mobile reception, data connection (GSM, 2G, 3G, LTE) Connection to the OCPP backend RFID card reader SIM card (controller) Micro SD card...
  • Page 15 Operation 4.2 Main menu Table 4- 2 Symbols of the charging point indicators Charging point number Active meter (value/status) Identification (meter) Vehicle status Plug status Charge point cover Charging status Circuit breaker status Meter status Available power Query to the meter The symbols are explained in the help menu.
  • Page 16: Charging

    Operation 4.3 Charging Charging Start charging Proceed as follows to start charging: 1. Check if the required charging point is ready for operation: The status LED must light up green. 2. You will see the following instruction on the display: "Press the button below the display and follow the instructions".
  • Page 17 Operation 4.3 Charging Completing the charging Your vehicle is being charged as long as the light pulsates in blue. Charging is complete when the light of the status indicator is constant. You can stop charging at any time. You have three different options for ending the charging process: Procedure with RFID card Proceed as follows to end the charging process with the RFID card: 1.
  • Page 18: Faults

    Faults Fault clearance Procedure in the event of a fault If the charging station experiences a fault, proceed as follows: 1. Check the icons on the display. You can find an overview of the icons in the table in the Main menu (Page 13) chapter.
  • Page 19 Faults 5.2 FAQs Symbol Meaning Solution Communication error (Mode 3) Disconnect the vehicle from the charging station and reconnect the vehicle. Check the vehicle. Check the charging cable. Check the charging station (plug and cable). Vehicle not connected Connect the charging cable to the vehicle and to the charging station.
  • Page 20 Faults 5.2 FAQs Symbol Meaning Solution Phase/line not available. Check whether the voltage on all lines L1 ... L3 is between 207 ... 255 V. 100% of the max. power (22 kW) is available 75% or less of the max. power (22 kW) is available 50% or less of the max.
  • Page 21 Faults 5.2 FAQs Symbol Meaning Solution Hardware fault Request service for repair. The charging station is not con- Check the network connection and the nected to the OCPP server. router setting. Invalid setting of OCPP server Check the OCPP server URLs. The PC has no connection to the Check the cabling.
  • Page 22 Faults 5.2 FAQs Symbol Meaning Solution < -25 °C Charging is not possible SICHARGE Operating Manual ERK Operating Manual, 07/2020, A5E48572458-AB...
  • Page 23: Appendix

    Appendix Information on weights and measures regulations Eichrechtliche Hinweise Folgende Hinweise gelten für die Bundesrepublik Deutschland. Am 17. März 2016 trat die Verordnung über technische Mindestanforderungen an den sicheren und interoperablen Aufbau und Betrieb von öffentlich zugänglichen Ladepunkten für Elektromobile (Ladesäulenverordnung - LSV) in Kraft. Sie schreibt u.a. die Anzeige von Ladepunkten bei der Bundesnetzagentur vor.
  • Page 24 Appendix A.1 Information on weights and measures regulations I Auflagen für den Betreiber der Ladeeinrichtung, die dieser als notwendige Voraussetzung für einen bestimmungsgemäßen Betrieb der Ladeeinrichtung erfüllen muss. Der Betreiber der Ladeeinrichtung ist im Sinne §31 des Mess- und Eichgesetzes der Verwender des Messgerätes.
  • Page 25 Appendix A.1 Information on weights and measures regulations § 33 Anforderungen an das Verwenden von Messwerten (1) Werte für Messgrößen dürfen im geschäftlichen oder amtlichen Verkehr oder bei Messungen im öffentlichen Interesse nur dann angegeben oder verwendet werden, wenn zu ihrer Bestimmung ein Messgerät bestimmungsgemäß...
  • Page 26 Appendix A.1 Information on weights and measures regulations 8. Der EMSP muss durch entsprechende Vereinbarungen mit dem Betreiber der Ladeeinrichtung sicherstellen, dass bei diesem die für Abrechnungszwecke genutzten Datenpakete ausreichend lange gespeichert werden, um die zugehörigen Geschäftsvorgänge vollständig abschließen zu können. 9.
  • Page 27: Retrieving Measured Values

    Appendix A.2 Retrieving measured values Retrieving measured values Retrieving the signed readings In order to obtain energy for the electric vehicle, you must be registered with an operator. With these login details, you can register with the operator of the charging station. After logging in with the operator, you can download the signed measurement data.
  • Page 28 Appendix A.2 Retrieving measured values Login to the provider 1. Open an Internet browser 2. Enter https://certifications.htb.solutions/ in the address line. 3. Click "Enter" 4. Sign in with your credentials Figure A-1 Login SICHARGE Operating Manual ERK Operating Manual, 07/2020, A5E48572458-AB...
  • Page 29 Appendix A.2 Retrieving measured values Charging stations 1. Select the tab Dashboard 2. Click DETAILS in the field Ladestationen Figure A-2 Charging stations SICHARGE Operating Manual ERK Operating Manual, 07/2020, A5E48572458-AB...
  • Page 30 Appendix A.2 Retrieving measured values Charging column Click on the data field for the corresponding charging column. Figure A-3 Charging column SICHARGE Operating Manual ERK Operating Manual, 07/2020, A5E48572458-AB...
  • Page 31 Appendix A.2 Retrieving measured values Charging processes Click the arrow next to DETAILS in the field Ladevorgänge. Figure A-4 Charging processes SICHARGE Operating Manual ERK Operating Manual, 07/2020, A5E48572458-AB...
  • Page 32 Appendix A.2 Retrieving measured values Selecting the charging process Select the charging process and click on the right of the appropriate field. Figure A-5 Charging process SICHARGE Operating Manual ERK Operating Manual, 07/2020, A5E48572458-AB...
  • Page 33 Appendix A.2 Retrieving measured values Signed measured values Click the Signierte Messwerte tab. Figure A-6 Signed measured values SICHARGE Operating Manual ERK Operating Manual, 07/2020, A5E48572458-AB...
  • Page 34 Appendix A.2 Retrieving measured values Downloading the measured values Click on the arrow to download the signed measured values of the charging process. Figure A-7 Download Result The file with the signed measured values in *.xml format, the selected charge process, is stored locally on your device.
  • Page 35: Transparency Software

    Appendix A.3 Transparency software Transparency software Installation and setup of the Transparenz software To install and commission the application, proceed as follows: 1. Download the Version of the Transparenz software (https://transparenz.software/) released by the German Federal Testing Laboratory (PTB) to your computer. 2.
  • Page 36 Appendix A.3 Transparency software 6. Click "Überprüfen", to check the signature. Figure A-8 Open/check the Transparenz software data record SICHARGE Operating Manual ERK Operating Manual, 07/2020, A5E48572458-AB...
  • Page 37 Appendix A.3 Transparency software Signature verification The result of the signature verification is displayed in a new window. In this signature window, you can see all the information that was contained in the signed data record. Figure A-9 Transaction transparency data record result SICHARGE Operating Manual ERK Operating Manual, 07/2020, A5E48572458-AB...
  • Page 38 Appendix A.3 Transparency software Checking the transaction After having selected the transaction in the overview of the open data records, click "Transaktion überprüfen“" to check the transaction. Figure A-10 Open transaction transparency software SICHARGE Operating Manual ERK Operating Manual, 07/2020, A5E48572458-AB...
  • Page 39 Appendix A.3 Transparency software Result The test result will now also show the difference between the start and the stop meter status. Figure A-11 Transaction transparency software result SICHARGE Operating Manual ERK Operating Manual, 07/2020, A5E48572458-AB...
  • Page 40: Quality Documentation

    A.4 Quality documentation Quality documentation CE marking SICHARGE CC AC22 charging station meets the general and safety-related requirements of the following directives, and conforms to the harmonized European standards (EN) for controllers published in the official journals of the European Community: •...
  • Page 41: List Of Abbreviations

    List of abbreviations Abbreviations EMSP Electromobility Service Provider Measured value users EVSE Electric Vehicle Supply Equipment RCCB Fault current OCPP Open Charge Point Protocol Public Key German Federal Testing Laboratory Pulse width modulation SICHARGE Operating Manual ERK Operating Manual, 07/2020, A5E48572458-AB...