2.8

Safety loop and emergency stop

The emergency stop of the charging station is triggered when the safety loop of the charging
station is interrupted. The safety loop includes by default the door contacts on the front and
rear. You can select additional equipment in the configuration process:
• Emergency Stop switch on the front
• Option for integration into an existing safety loop
• Connection of an external load management system
Triggering the emergency stop
The safety loop of the charging station can be interrupted by opening the doors, actuating
the Emergency Stop switch, or triggering the external safety loop or the load management
system. The emergency stop then triggers immediately.
The section "Error message "Emergency Stop was triggered" (Page 119)" describes various
other error scenarios and the respective behavior of the charging station in each case in
addition to the emergency stop.
Position of the Emergency Stop switch
The optional Emergency Stop switch is located in the middle of the front of the charging
station, below the also optional AC charging socket. Its recessed position protects it from
unintentional operation.
Figure 2-4  Position of the switch
Function of the switch
The function of the switch is described in detail in the section "Emergency Stop switch (Page
36)".
SICHARGE D
Operating Instructions, 11/2023, A5E50556539-AG