Connecting the Ethernet cables
If you want to establish a connection between the OCPP backend and the charging station via
Ethernet, you must connect the Ethernet cable to the port (‑FA6) (see figure below). If you
want to operate the charging station together with an external load management system
(ELMS) connect the Ethernet cable between the ELMS and charging station to the right port
-FA13. The connection between the ELMS and charging station has to be mechanically
guarded so that no third party can undo the connection and make a connection themselves.
Secure the cables with a strain relief. These terminals also take on the function of overvoltage
protection.
Figure 5-32  Terminals of the Ethernet cables
SICHARGE D
Operating Instructions, 11/2023, A5E50556539-AG
Dispenser 1
Dispenser 2 (not used)
Ethernet port for Router 2 (-XF4)
ELMS
Installation and mounting
5.6 Connecting the charging station
101