Protocol Decoding
15.1.2
Bus Setting
Set the Bus
Click or tap the drop-down button of BUS to select the desired bus. Available options
include analog channels CH1-CH4. You can also self-define the bus.
Table 15.1 Bus Setting
Bus
CH1
CH2
CH3
CH4
User
Set the Width
When the "BUS" setting is set to "User", you can set the bus width. Click or tap the
input field of Width, and then use the pop-up numeric keypad to set the width. You
can also use the corresponding multipurpose knob to set the value.
Specify data channel for each bit
When the "BUS" setting is set to "User", you can specify the data channel for each bit.
Click or tap Bit X set the bit of the channel. By default, 0 is selected. Its available
range is from 0 to (width - 1).
Click or tap the drop-down button of CH to select the data channels for a bit.
Available sources include analog channels CH1-CH4.
DHO800 User Guide
170
Width
Bit X
1
0
1
0
1
0
1
0
1 (Default)
0 (Default)
to 4
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
Channel
Remarks
Width, Bit X, and CH are set
CH1
automatically, and you
cannot modify them.
Width, Bit X, and CH are set
CH2
automatically, and you
cannot modify them.
Width, Bit X, and CH are set
CH3
automatically, and you
cannot modify them.
Width, Bit X, and CH are set
CH4
automatically, and you
cannot modify them.
-
-