18.1.2
DHO900 User Guide
1.888.610.7664
196

Bus Setting

Set the Bus
Click or tap the drop-down button of BUS to select the desired bus. Available options
include analog channels CH1-CH4 or digital channels D0-D15. You can also self-
define the bus. Only when the digital channel probe is connected, can you select the
digital channel (D0-D15) as the bus.

Table 18.1 Bus Setting

Bus
Width
CH1
1
CH2
1
CH3
1
CH4
1
D7-D0
8
D15-D8
8
D15-D0
16
D0-D7
8
www.calcert.com
15
10
20
5
25
0
30
Bit X
Channel
0
CH1
0
CH2
0
CH3
0
CH4
0 (Default)
D7 (Default)
D15
0 (Default)
(Default)
D15
0 (Default)
(Default)
0 (Default)
D0 (Default)
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
Remarks
Width, Bit X, and CH are set
automatically, and you
cannot modify them.
Width, Bit X, and CH are set
automatically, and you
cannot modify them.
Width, Bit X, and CH are set
automatically, and you
cannot modify them.
Width, Bit X, and CH are set
automatically, and you
cannot modify them.
Bit0 to Bit7 are set to D7 to
D0 respectively. Width is set
automatically, and you
cannot modify them.
Bit0 to Bit7 are set to D15
to D8 respectively. Width is
set automatically, and you
cannot modify them.
Bit0 to Bit15 are set to D15
to D0 respectively. Width is
set automatically, and you
cannot modify them.
Bit0 to Bit7 are set to D0 to
D7 respectively. Width is set
sales@calcert.com