Triggering the Oscilloscope
8.7.6

Duration Trigger

In duration trigger, the oscilloscope identifies a trigger condition by searching for the
duration of a specified pattern. This pattern is a logical "AND" combination of the
channels. Each channel can be set to 1 (high), 0 (low), or X (don't care). The
instrument triggers when the duration (∆T) of this pattern meets the preset time, as
shown in the figure below.
Trigger Type
Click or tap the drop-down button of Type to select "Duration".
DHO800 User Guide
78
∆T
CH1
CH2
CH3
CH4

Figure 8.11 Duration Trigger