14.2.3 PM ............................176 15 Bode Plot (for DHO914S and DHO924S only) ..........15.1 Basic Setting ............................. 15.1.1 To Enable or Disable the Bode Function ..............179 15.1.2 To Start or Stop the Operation ..................179 15.1.3 To Set the Input Source ....................
Do not expose the battery (if available) to high temperature or fire. Keep it out of the reach of children. Improper change of a battery (lithium battery) may cause an explosion. Use the RIGOL specified battery only. • Handle with Caution.
Novel and delicate industrial design, easy to operate • Unique online upgrade The DHO900 series is RIGOL's high-performance economical digital oscilloscope. Though compact in design, it has superior performance. It features a capture rate up to 1,000,000 wfms/s (in UltraAcquire Mode), 50 Mpts memory depth, 12 bits resolution, and low noise.
This manual gives you a quick overview of the front and rear panel, user interface as well as basic operation methods of DHO900 series. For the latest version of this manual, download it from RIGOL official website Publication Number UGA37100-1110 Software Version Software upgrade might change or add product features.
Page 25
SCALE Knob Content Conventions in this Manual DHO900 series digital oscilloscope includes the following models. Unless otherwise specified, this manual takes DHO924S as an example to illustrate the operation methods of DHO900 series. Model Max. Analog Bandwidth No. of Analog Channels...
The consigner or carrier shall be liable for the damage to the instrument resulting from shipment. RIGOL would not be responsible for free maintenance/rework or replacement of the instrument. 2. Inspect the instrument...
Output DC, 12 V, 4 A, 48 W CAUTION The power adaptor provided in accessories can only be used to power RIGOL instruments. Do not use it for mobile phone and other devices. WARNING To avoid electric shock, ensure that the instrument is correctly grounded.
Setup > Language to select the system language. 4.3.5 To Connect the Probe RIGOL provides passive probes and logic probes (optional) for DHO900 series. For specific probe models, refer to DHO900 Data Sheet. For detailed technical information of the probes, please refer to the corresponding Probe User Guide.
"Perfectly compensated" waveform shown in the above figure. Product Overview Unless otherwise specified, this chapter takes DHO924S as an example to introduce the appearance and dimensions, front and rear panels, and user interface of the DHO900 series oscilloscope.
Page 38
AFG key (for DHO914S and DHO924S only). Press this key to enable/disable the AFG output. When the AFG output is enabled, press this key to open the AFG setting menu. In this menu, you can set the AFG waveform parameters and enable/disable the waveform output.
2. AFG OUT (for DHO914S and DHO924S only) DHO914S and DHO924S have a built-in AFG. When the AFG output is enabled, the rear-panel [AFG OUT] connector will output signals according to current settings. 3. LAN Connect the instrument to network via this interface.
In the trigger debugging process of video signals, the frequency in different part of the signal can be reflected by a different brightness, as RIGOL's digital oscilloscope provides the intensity graded color display function. Experienced users can quickly judge the signal quality and discover abnormalities during the debugging process.
Function/Arbitrary Waveform Generator (for DHO914S and DHO924S only) The DHO914S and DHO924S series have a standard built-in 25 MHz Function/ Arbitrary Waveform Generator (AFG), which integrates the signal source and the oscilloscope into one, providing great convenience for engineers who need to use the signal source and oscilloscope at the same time.
OK to load the selected waveform. For details, refer to 14.2 Modulation The built-in Function/Arbitrary Waveform Generator of DHO914S and DHO924S supports amplitude modulation (AM), frequency modulation (FM), and phase modulation (PM). A modulated waveform consists of a carrier waveform and a modulating waveform.
Through the analysis on the system's gain and phase margins, you can determine the stability of the system. With the built-in signal generator module, the DHO914S and DHO924S series generate the sweep signal of a specified frequency range and outputs to the switch power supply circuit under test.
1. File Header There is only one file header in a binary file. The file header contains the following information. Table 23.2 File Header Two-byte characters, RG, indicating that the file is the RIGOL Cookie binary data file format. Version Two-byte, indicating the file version.
PC. The remote control can be realized by using SCPI (Standard Commands for Programmable Instruments) commands. This chapter will illustrate how to use the RIGOL Ultra Sigma software to remotely control the instrument via various interfaces. CAUTION Before connecting the communication cable, please turn off the instrument to avoid causing damage to the communication interfaces.
PC via the USB interface. You can also click USB-TMC to search for the resource. 3. View the device resource The resources found will appear under the "RIGOL Online Resource" directory, and the model number and USB interface information of the instrument will also be displayed.
Page 275
4. View the device resource The resources found will appear under the "RIGOL Online Resource" directory. 5. Control the instrument remotely Right-click the device resource name and select "SCPI Panel Control" to open the remotely command control panel.
27.2 Appendix B: Warranty RIGOL TECHNOLOGIES CO., LTD. (hereinafter referred to as RIGOL) warrants that the product mainframe and product accessories will be free from defects in materials and workmanship within the warranty period. If a product proves defective within the warranty period, RIGOL guarantees free replacement or repair for the defective product.
RIGOL be liable for any consequential, indirect, ensuing, or special damages for any breach of warranty in any case. 27.3 Appendix C: Factory Settings Press the front-panel or click/tap Default on the Toolbar and a prompt message "Restore default settings?" is displayed. Click or tap OK to restore the instrument to its factory default settings, as shown in the table below.
Need help?
Do you have a question about the DHO924S and is the answer not in the manual?
Questions and answers