PHOTOCONDUCTOR UNIT (PCU)

3.7.5 CLEANING BLADE

• Remove the PCU. ( 3.7.1)
• Remove the OPC drum ( 3.7.3)
• Remove the charge roller, cleaning roller ( 3.7.4)
[A]: Cleaning blade (
Reinstallation: Cleaning Blade
• To prevent damage to the new cleaning blade and OPC drum, apply some toner
to the edge of the new blade [B].
• Install the new blade. Remove some toner from the edge of the old blade with
your finger, and apply it evenly along the full length of the new blade.
[A]
x2)
3-22
[B]
B205R154.WMFF