SERVICE PROGRAM MODE
SP7XXX: Data Log
7001*
Main Motor Operation Time
The number of prints and drive time for drum revolutions can be obtained by
counting the main motor revolution time. If the amount of the time required for the
drum to revolve to print 1 copy increases, this data combined with the number of
copies can be used to analyze problems and could be useful for future product
development.
Display: 0000000~9999999 min.
7401*
Total SC Counter
Displays the total number of service calls that have occurred.
7403*
SC History
7403 1
Latest
7403 2
Latest 1
7403 3
Latest 2
7403 4
Latest 3
7403 5
Latest 4
7403 6
Latest 5
7403 7
Latest 6
7403 8
Latest 7
7403 9
Latest 8
7403 10
Latest 9
7502*
Total Paper Jam Counter
Displays the total number of paper jams.
7503*
Total Original Jam Counter
Displays the total number of original jams.
Displays the most recent 10 service calls.
5-76