Drum, Id Sensor, And Cleaning Blade - Ricoh BE-C1 D046 Field Service Manual

Table of Contents

Advertisement

Drum, ID Sensor, and Cleaning Blade

Preparation
• Remove the development unit * p.301
• To the right of the drum drive gear, loosen the screw to relieve the tension on the drive belt.
1. Remove
[1] Drum drive gear and belt ( x 2, use a hex wrench)
[2] ID sensor connector ( x 1)
[3] Left drum bracket ( x 2)
[4] Right drum bracket ( x 2)
[5] OPC drum assembly
2. Cover the OPC with a sheet of paper to protect it from light.
• Never touch the surface of the drum.
Drum, Development Unit