Find Quality Products Online at:
SCPI Commands
*CLS ......................................................................... 124

*ESE ......................................................................... 124

*ESR ......................................................................... 125
*IDN ........................................................................ 125
*OPC ........................................................................ 125
*OPT ........................................................................ 126
*RST ......................................................................... 126
*SRE ......................................................................... 126
*STB ......................................................................... 127
*TRG ........................................................................ 127
*CLS
Clears the standard event status register, extended
Description
event status register, and error queue.
Syntax
*CLS
*ESE
Sets or returns the ESER (Event Status Enable
Description
Register) contents.
Syntax
*ESE <NR1>
Query Syntax
*ESE?
Parameter/
<NR1>
Return parameter
Example
*ESE 65
Set the ESER to 01000001
*ESE?
->130
ESER=10000010
124
GlobalTestSupply
www.
T3PM1100 User Manual
Set
Set
0~255
Query
.com