Adjustment In The Case Of Canceling Limit For Tray Stack - Canon Finisher-AK1 Service Manual

Table of Contents

Advertisement

5
Adjustment > Adjustment at Time of Parts Replacement > Adjustment in the Case of Canceling Limit for Tray Stack > Procedure
Adjustment in the Case of Canceling Limit for Tray
Stack
Execute this adjustment in the case of canceling the limit for tray stacking of coated paper or
extra-length paper or replacing the finisher controller PCB.
[B]
[A]
[A] Normal stacking
[B] Stacking while stacking limit is cancelled
NOTE:
This adjustment is for the lower tray only. Thus, cancellation of the stacking limit for the
upper tray is not available.
Following table shows stacking capacity for the lower tray while the stacking limit is
cancelled.
Paper type
At normal operation
Less than 64
gsm
Half
80 gsm or less
Plain paper
Over 80 gsm
Stitching
200 sets or 3,000 sheets
Extra-large
Up to 147 mm in height
80 gsm or less
Coated
Half
Over 80 gsm
paper
Stitching
200 sets or 3,000 sheets
Extra-large
Up to 147 mm in height
5
Adjustment > Adjustment at Time of Parts Replacement > Adjustment in the Case of Canceling Limit for Tray Stack > Procedure
F-5-141
When stacking limit is
canceled
1,000 sheets
Up to 147 mm in height
4,000 sheets
Up to 490 mm in height
3,000 sheets
Up to 147 mm in height
200 sets
Up to 216 mm in height
4,000 sheets
Up to 490 mm in height
3,000 sheets
Up to 490 mm in height
200 sets
Up to 216 mm in height
T-5-7
■ Preparations
1) Turn ON the power of the finisher.
2) Turn ON the power of the host machine to be on to be on standby.
3) Open the front cover and put the door switch tool into the door switch.
4) Remove the switch cover.
NOTE:
Refer to "Preparations 5-6" for details of step 1) to 4).
■ Procedure
1) Set DIP SW382 [1] on the switch PCB as shown in the figure below.
[1]
SW382
SW381
SW383
SW384 SW385
(-)
(+)
ENTER
F-5-142
5-60
5-60

Advertisement

Table of Contents
loading

This manual is also suitable for:

Finisher-ak2

Table of Contents