8
Path: <Device> - Basic system - Users –
8.2.3
Time service SFB settings and system time
action
Time Service is a System Function Block (SFB) of the Basic System. The following
areas can be parameterized with the Time Service:
General
l
Daylight saving
l
NTP
l
Contract hour
l
Parameters and export values are documented in detail in the online help. Select
Time Service in the expanded parameter tree of the parameterization window and
press [F1].
Time-related values and actions
Check or set the following settings:
Time zone local time zone of the device (relative to UTC)
Prim. external time source Sec. external time source
The device time can be changed directly on the device, via enSuite or via external
time sources.
Max. Synchronization window maximum changeable difference of the system
time
Synchronization interval Synchronization only possible within this time interval
Time update mode Synchronize system time only or also set
Error on refused time setting Behavior if takeover of external time rejected.
Message on failure or ext. time source(s)
Behavior if all parameterized external time sources are disturbed:
Daylight saving changeover from normal time (≙ "winter time") to daylight saving
time and vice versa.
NTP the enCore device can synchronize its system time via Network Time Protocol
(short: NTP) against highly accurate time servers.
Contrakt hour Contractual times and duration of the gas day
Parameters and export values are documented in detail in the online help, press
[F1].
GasLab Q2
Configuration and analysis software enSuite
Special user rights tab
Fig. 8-17: Störungen quittieren Benutzerrechte