Fig. 13 Representation Potentiometer Measurement Range - Beckhoff EPP3504-0023 Short Manual

4-channel measuring bridge,(sg) full/half/quarter bridge, 24 bit, 10 ksps
Hide thumbs Also See for EPP3504-0023:
Table of Contents

Advertisement

Product overview
Measurement mode
Common-mode rejection ratio (with 50 Hz FIR filter)
Temperature coefficient, typ.
Largest short-term deviation during a specified
electrical interference test
Input impedance
(internal resistance)
2
) A regular offset adjustment with connected potentiometer is recommended. The given offset specification
of the box module is therefore practically irrelevant. Therefore, specification values with and without offset
are given here. In practice, the offset component can be eliminated by the functions Tare and also
ZeroOffset [} 000] of the box module or in the controller by a higher-level tare function. The offset deviation
over time can change, therefore Beckhoff recommends a regular offset adjustment or careful observation of
the change.
3
) Values related to a common mode interference between SGND and internal ground.
Potentiometer measurement range
Fig. 13: Representation potentiometer measurement range
Note: In Extended Range Mode the Underrange/Overrange display in the PDO status has the character of an information/warning
when the nominal measuring range is exceeded, i.e. no Error is displayed in the PDO status and LED. If the technical measuring range
is also exceeded, Error = TRUE is also displayed. The detection limit for Underrange/Overrange Error can be set in the CoE.
In Legacy Range mode, an Underrange/Overrange event also leads to an Error in the PDO status.
32
Potentiometer (3/5-wire)
3)
DC:
tbd
Tc
< 2 ppm/K
Gain
Tc
< 2 ppm
Offset
tbd %
tbd
Version: 1.2
50 Hz:
 typ.
tbd
 typ.
/K
FSV
= tbd ppm
typ.
FSV
FSV
1 kHz:
tbd 
 typ.
EPP3504-0023