Commissioning
Fig. 20: Filter coefficients Nos. 1 to 12 of channel 1 in the CoE online of an ELM3602 EtherCAT Terminal
In case of device replacement
If the coefficients should/have to be reloaded into the new device after a device exchange, they can be
stored in a StartUp list:
Fig. 21: StartUp list of an ELM3602 EtherCAT Terminal, already partially modified by direct input
A total of up to 40 coefficients (i.e. 160 bytes) can be stored there for this device. These are now to be
extracted from the box module "in one set", alternatively they could also be copied out manually one after the
other as above.
After installing the TF6010 ADS Monitor from the Beckhoff website, it can be started in the development
environment menu under [TwinCAT] → [ADS Monitor]:
62