Beckhoff EPP3504-0023 Short Manual page 225

4-channel measuring bridge,(sg) full/half/quarter bridge, 24 bit, 10 ksps
Hide thumbs Also See for EPP3504-0023:
Table of Contents

Advertisement

Text ID
Type
Place
0x8284
Error
Communication Key loading failed
0x8285
Error
Communication Reading Public Key failed: %X
0x8286
Error
Communication Reading Public EK failed: %X
0x8287
Error
Communication Reading PCR Value failed: %X
0x8288
Error
Communication Reading Certificate EK failed: %X
0x8289
Error
Communication Challenge could not be hashed:
0x828A
Error
Communication Tickstamp Process failed
0x828B
Error
Communication PCR Process failed: %X
0x828C
Error
Communication Quote Process failed: %X
0x82FF
Error
Communication Bootmode not activated
0x8300
Error
Encoder
0x8301
Error
Encoder
0x8302
Error
Encoder
0x8303
Error
Encoder
0x8304
Error
Encoder
0x8305
Error
Encoder
0x8306
Error
Encoder
0x8307
Error
Encoder
0x8308
Error
Encoder
0x8309
Error
Encoder
0x830A
Error
Encoder
0x830C
Error
Encoder
0x830D
Error
Encoder
0x8310
Error
Encoder
0x8311
Error
Encoder
0x8312
Error
Encoder
0x8313
Error
Encoder
0x8314
Error
Encoder
0x8315
Error
Encoder
0x8400
Error
Drive
0x8401
Error
Drive
0x8402
Error
Drive
0x8403
Error
Drive
0x8404
Error
Drive
0x8405
Error
Drive
0x8406
Error
Drive
0x8407
Error
Drive
0x8408
Error
Drive
0x8409
Error
Drive
EPP3504-0023
Text Message
%X
Set position error: 0x%X, %d
Encoder increments not
configured: 0x%X, %d
Encoder error
Encoder power missing (channel
%d)
Encoder communication error,
channel: %X
EnDat2.2 is not supported,
channel: %X
Delay time, tolerance limit
exceeded, 0x%X, channel: %X
Delay time, maximum value
exceeded, 0x%X, channel: %X
Unsupported ordering
designation, 0x%X, channel: %X
(only 02 and 22 is supported)
Encoder CRC error, channel: %X Encoder CRC error
Temperature %X could not be
read, channel: %X
Encoder Single-Cycle-Data Error,
channel. %X
Encoder Watchdog Error,
channel. %X
Initialisation error
Maximum frequency of the input
signal is exceeded (channel %d)
Encoder plausibility error
(channel %d)
Configuration error (channel %d)
Synchronisation error
Error status input (channel %d)
Incorrect drive configuration:
0x%X, %d
Limiting of calibration velocity:
%d, %d
Emergency stop activated: 0x%X,
%d
ADC Error
Overcurrent
Invalid modulo position: %d
DC-Link undervoltage (Error)
DC-Link overvoltage (Error)
I2T-Model Amplifier overload
(Error)
I2T-Model motor overload (Error)
Version: 1.2
Additional comment
Boot mode not activated
Error while setting the position
Encoder increments not configured
The amplitude of the resolver is too small
Encoder communication error
EnDat2.2 is not supported
Runtime measurement, tolerance exceeded
Runtime measurement, maximum value exceeded
Wrong EnDat order ID
Temperature cannot be read
CRC error detected. Check the transmission path and
the CRC polynomial
The sensor has not responded within a predefined time
period
Drive incorrectly configured
Limitation of the calibration velocity
Emergency stop activated
Error during current measurement in the ADC
Overcurrent in phase U, V or W
Modulo position invalid
The DC link voltage of the terminal is lower than the
parameterized minimum voltage. Activation of the
output stage is prevented.
The DC link voltage of the terminal is higher than the
parameterized maximum voltage. Activation of the
output stage is prevented.
• The amplifier is being operated outside the
specification.
• The I2T-model of the amplifier is incorrectly
parameterized.
• The motor is being operated outside the
parameterized rated values.
Appendix
225

Advertisement

Table of Contents
loading

Table of Contents