Beckhoff EPP3504-0023 Short Manual page 17

4-channel measuring bridge,(sg) full/half/quarter bridge, 24 bit, 10 ksps
Hide thumbs Also See for EPP3504-0023:
Table of Contents

Advertisement

Common data
Electrical isolation channel/SGND
Configuration
Note to cable length
1
) see chapters Self-test and self-test report and Connection test/switchable connection diagnostics
2
) see notes to potential groups within chapter Power supply, potential groups
Basic mechanical
properties
Connection type
Dimensions (W x H x D)
Mounting
Note mounting
Weight
Permissible ambient temperature range
during operation
Permissible ambient temperature range
during storage
Environmental data
Permissible operating altitude range
Relative humidity
Protection class
Normative data
Vibration-/shock resistance
EMC-resistance / emission
)
Approvals/ markings *
EMC notes
*) Real applicable approvals/markings see type plate on the side (product marking).
EPP3504-0023
EPP3504-0023
2)
Functional insulation, 707 V DC (type test)
Via the EtherCAT Master, e.g. TwinCAT
Signal cable lengths to the sensor / encoder over 3 m must be
shielded, the shield design must be in line with the state of the
art and be effective. For larger cable lengths >30 m a suitable
surge protection should be provided if appropriate
interference could affect the Signal cable.
EPP3504-0023
Push-In spring-loaded terminal PC FMC 1.5
6‑pin, RM 2.54 mm
Pluggable, 25 mating cycles
See chapter "Mounting and wiring"/ "Mounting"/
"Dimensions" [} 203]
Directly on metallic, earthed structure screwed
Plug partly not within scope of delivery, see chapter
Notes on connection technology EPP3504-0023 [} 210]
approx. 250 g
0...+55 °C
-25...+85 °C
EPP3504-0023
0 up to 2000 m (derating at higher altitudes on request)
max. 95%, no condensation
IP 20 (because of plug connectors)
EPP3504-0023
Conforms to EN 60068-2-6 / EN 60068-2-27
Conforms to EN 61000-6-2 / EN 61000-6-4
CE, UKCA, EAC
In case of push-in connectors, ESD air discharges conforming
to EN 61000-6-4 into the connectors or to the lines connected
there can lead to measurement deviations up to ±FSV within
the respective channel or to other channels by crosstalk.
Peak voltages (surge) conforming to EN 61000-6-2 that are
applied to the cable shield can lead to measurement
deviations up to ±FSV.
Version: 1.2
Product overview
17

Advertisement

Table of Contents
loading