Beckhoff EPP3504-0023 Short Manual page 221

4-channel measuring bridge,(sg) full/half/quarter bridge, 24 bit, 10 ksps
Hide thumbs Also See for EPP3504-0023:
Table of Contents

Advertisement

If the function is to be deactivated because, for example, many messages come in or the EventLogger is not
used, the StartUp entry can be deleted or set to 0. The value can then be set back to 1 later from the PLC
via CoE access if required.
Reading messages into the PLC
- In preparation - [} 106]
Interpretation
Time stamp
The time stamp is obtained from the local clock of the terminal at the time of the event. The time is usually
the distributed clock time (DC) from register x910.
Please note: When EtherCAT is started, the DC time in the reference clock is set to the same time as the
local IPC/TwinCAT time. From this moment the DC time may differ from the IPC time, since the IPC time is
not adjusted. Significant time differences may develop after several weeks of operation without a EtherCAT
restart. As a remedy, external synchronization of the DC time can be used, or a manual correction
calculation can be applied, as required: The current DC time can be determined via the EtherCAT master or
from register x901 of the DC slave.
Structure of the Text ID
The structure of the MessageID is not subject to any standardization and can be supplier-specifically
defined. In the case of Beckhoff EtherCAT devices (EL, EP) it usually reads according to xyzz:
x
0: Systeminfo
2: reserved
1: Info
4: Warning
8: Error
Example: Message 0x4413 --> Drive Warning Number 0x13
Overview of text IDs
Specific text IDs are listed in the device documentation.
Text ID
Type
Place
0x0001
Information
System
0x0002
Information
System
0x0003
Information
System
0x1000
Information
System
0x1012
Information
System
0x1021
Information
System
0x1024
Information
System
0x1042
Information
System
0x1048
Information
System
0x1084
Information
System
EPP3504-0023
y
0: System
1: General
2: Communication
3: Encoder
4: Drive
5: Inputs
6: I/O general
7: reserved
Text Message
No error
Communication established
 Initialization: 0x%X, 0x%X, 0x%X General information; parameters depend on event. See
Information: 0x%X, 0x%X, 0x%X General information; parameters depend on event. See
EtherCAT state change Init -
PreOp
EtherCAT state change PreOp -
Init
EtherCAT state change PreOp -
Safe-Op
EtherCAT state change SafeOp -
PreOp
EtherCAT state change SafeOp -
Op
EtherCAT state change Op -
SafeOp
Version: 1.2
zz
Error number
Additional comment
No error
Connection established
device documentation for interpretation.
device documentation for interpretation.
Appendix
221