Fig. 7 Representation ±80 Mv Measurement Range - Beckhoff EPP3504-0023 Short Manual

4-channel measuring bridge,(sg) full/half/quarter bridge, 24 bit, 10 ksps
Hide thumbs Also See for EPP3504-0023:
Table of Contents

Advertisement

Fig. 7: Representation ±80 mV measurement range
Note: In Extended Range Mode the Underrange/Overrange display in the PDO status has the character of an information/warning
when the nominal measuring range is exceeded, i.e. no Error is displayed in the PDO status and LED. If the technical measuring range
is also exceeded, Error = TRUE is also displayed. The detection limit for Underrange/Overrange Error can be set in the CoE.
In Legacy Range mode, an Underrange/Overrange event also leads to an Error in the PDO status.