Tceventlogger And Io - Beckhoff EPP3504-0023 Short Manual

4-channel measuring bridge,(sg) full/half/quarter bridge, 24 bit, 10 ksps
Hide thumbs Also See for EPP3504-0023:
Table of Contents

Advertisement

Appendix
Text ID
Type
Place
0x840A
Error
Drive
0x8415
Error
Drive
0x8416
Error
Drive
0x8417
Error
Drive
0x841C
Error
Drive
0x8550
Error
Inputs
0x8551
Error
Inputs
0x8552
Error
Inputs
0x8553
Error
Inputs
0x8581
Error
Inputs
0x8600
Error
General IO
0x8601
Error
General IO
0x8602
Error
General IO
0x8603
Error
General IO
0x8610
Error
General IO
0x8611
Error
General IO
0x8612
Error
General IO
0x8613
Error
General IO
0x8700
Error
0x8701
Error
0x8702
Error
0x8703
Error
0x8704
Error
0x8705
Error
0x8706
Error
0x8707
Error
0x8708
Error
0x8709
Error
0x870A
Error
0x870B
Error
0xFFFF
Information
8.2

TcEventLogger and IO

The TwinCAT 3 EventLogger provides an interface for the exchange of messages between TwinCAT
components and non-TwinCAT components.
226
Text Message
Overall current threshold
exceeded
Invalid modulo factor: %d
Motor overtemperature
Maximum rotating field velocity
exceeded
STO while the axis was enabled
Zero crossing phase %X missing Zero crossing phase %X missing
Phase sequence Error
Overcurrent phase %X
Overcurrent neutral wire
Wire broken Ch %D
Wrong supply voltage range
Supply voltage to low
Supply voltage to high
Over current of supply voltage
Wrong output voltage range
Output voltage to low
Output voltage to high
Over current of output voltage
Channel/Interface not calibrated
Operating time was manipulated
Oversampling setting is not
possible
No slave controller found
Slave controller is not in
Bootstrap
Processor usage to high (>=
100%%)
Channel in saturation
Channel overload
Overloadtime was manipulated
Saturationtime was manipulated
Channel range error
no ADC clock
Debug: 0x%X, 0x%X, 0x%X
Version: 1.2
Additional comment
• The I2T-model of the motor is incorrectly
parameterized.
Total current exceeded
Modulo factor invalid
The internal temperature of the motor exceeds the
parameterized error threshold. The motor stops
immediately. Activation of the output stage is
prevented.
Rotary field speed exceeds the value specified for dual
use (EU 1382/2014).
An attempt was made to activate the axis, despite the
fact that no voltage is present at the STO input.
Wrong direction of rotation
Overcurrent phase %X
Overcurrent neutral wire
Wire broken Ch %d
Supply voltage not in the correct range
Supply voltage too low
Supply voltage too high
Overcurrent of supply voltage
Output voltage not in the correct range
Output voltage too low
Output voltage too high
Overcurrent of output voltage
Channel/interface not synchronized
Operating time was manipulated
Oversampling setting not possible
No slave controller found
Slave controller is not in bootstrap
Processor load too high (>= 100%%)
Channel in saturation
Channel overload
Overload time was manipulated
Saturation time was manipulated
Measuring range error for the channel
No ADC clock available
Debug: 0x%X, 0x%X, 0x%X
EPP3504-0023