Beckhoff EPP3504-0023 Short Manual page 223

4-channel measuring bridge,(sg) full/half/quarter bridge, 24 bit, 10 ksps
Hide thumbs Also See for EPP3504-0023:
Table of Contents

Advertisement

Text ID
Type
Place
0x4005
Warning
System
0x4006
Warning
System
0x4007
Warning
System
0x4008
Warning
System
0x4101
Warning
General
0x4102
Warning
General
0x417F
Warning
General
0x428D
Warning
General
0x4300
Warning
Encoder
0x4301
Warning
Encoder
0x4302
Warning
Encoder
0x4303
Warning
Encoder
0x4304
Warning
Encoder
0x4400
Warning
Drive
0x4401
Warning
Drive
0x4402
Warning
Drive
0x4405
Warning
Drive
0x4410
Warning
Drive
0x4411
Warning
Drive
0x4412
Warning
Drive
0x4413
Warning
Drive
0x4414
Warning
Drive
0x4415
Warning
Drive
0x4416
Warning
Drive
0x4417
Warning
Drive
0x4418
Warning
Drive
0x4419
Warning
Drive
EPP3504-0023
Text Message
%s: %s Connection Open (IN:%d
OUT:%d) from %d.%d.%d.%d
denied (Error: %u)
%s: %s Connection Open (IN:%d
OUT:%d) from %d.%d.%d.%d
denied (Input Data Size expected:
%d Byte(s) received: %d Byte(s))
%s: %s Connection Open (IN:%d
OUT:%d) from %d.%d.%d.%d
denied (Output Data Size
expected: %d Byte(s) received:
%d Byte(s))
%s: %s Connection Open (IN:%d
OUT:%d) from %d.%d.%d.%d
denied (RPI:%dms not supported
-> API:%dms)
Terminal-Overtemperature
Discrepancy in the PDO-
Configuration
Warning: 0x%X, 0x%X, 0x%X
Challenge is not Random
Subincrements deactivated: %d,
%d
Encoder-Warning
Maximum frequency of the input
signal is nearly reached (channel
%d)
Limit counter value was reduced
because of the PDO configuration
(channel %d)
Reset counter value was reduced
because of the PDO configuration
(channel %d)
Drive is not calibrated: %d, %d
Starttype not supported: 0x%X,
%d
Command rejected: %d, %d
Invalid modulo subtype: %d, %d
Target overrun: %d, %d
DC-Link undervoltage (Warning)
DC-Link overvoltage (Warning)
I2T-Model Amplifier overload
(Warning)
I2T-Model Motor overload
(Warning)
Speed limitation active
Step lost detected at position:
0x%X%X
Motor overtemperature
Limit: Current
Limit: Amplifier I2T-model
exceeds 100%%
Version: 1.2
Additional comment
Overtemperature. The internal temperature of the
terminal exceeds the parameterized warning threshold.
The selected PDOs do not match the set operating
mode.
Sample: Drive operates in velocity mode, but the
velocity PDO is but not mapped in the PDOs.
Sub-increments deactivated (despite activated
configuration)
General encoder error
Drive is not calibrated
Start type is not supported
Command rejected
Modulo sub-type invalid
Target position exceeded
The DC link voltage of the terminal is lower than the
parameterized minimum voltage. Activation of the
output stage is prevented.
The DC link voltage of the terminal is higher than the
parameterized maximum voltage. Activation of the
output stage is prevented.
• The amplifier is being operated outside the
specification.
• The I2T-model of the amplifier is incorrectly
parameterized.
• The motor is being operated outside the
parameterized rated values.
• The I2T-model of the motor is incorrectly
parameterized.
The maximum speed is limited by the parameterized
objects (e.g. velocity limitation, motor speed limitation).
This warning is output if the set velocity is higher than
one of the parameterized limits.
Step loss detected
The internal temperature of the motor exceeds the
parameterized warning threshold
Limit: current is limited
The threshold values for the maximum current were
exceeded.
Appendix
223